RECOGNIZE THIS SYMBOL
AS A SAFETY PRECAUTION.
ATTENTION INSTALLING PERSONNEL
Prior to installation, thoroughly familiarize yourself with this Installation Manual.
Observe all safety warnings. During installation or repair, caution is to be observed.
It is your responsibility to install the product safely and to educate the customer on its safe use.
ARUF**14**/ARPT**14**
1 Important Safety Instructions
The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards. It
is the owner’s and installer’s responsibility to read and com-
ply with all safety information and instructions accompanying
these symbols. Failure to heed safety information increases
the risk of personal injury, property damage, and/or product
damage.
ASPT**14**/ASUF**14**
AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS
Contents
1 Important Safety Instructions .................................. 1
2 Shipping Inspection ................................................. 2
2.1 Parts ........................................................................3
2.2 Handling ..................................................................3
3 Codes & Regulations................................................ 3
4 Replacement Parts ................................................... 3
5 Pre-Installation Considerations .............................. 3
5.1 Preparation ..............................................................3
5.2 System Matches ......................................................3
5.3 Interconnecting Tubing ............................................3
5.4 Clearances ..............................................................3
5.5 Horizontal Applications ............................................4
6 Installation Location ................................................ 4
6.1 Upflow Installation....................................................4
6.2 Horizontal Left Installation .......................................4
6.3 Downflow/Horizontal Right Installation ....................5
7 Refrigerant Lines ...................................................... 7
7.1 Tubing Size ..............................................................7
7.2 Tubing Preparation ..................................................7
7.3 Special Instructions .................................................8
7.4 Tubing Connections for Flowrator Model .................8
7.5 Tubing Connections for TXV Models .......................8
8 Condensate Drain Lines........................................... 9
9 Ductwork ................................................................... 9
9.1 Return Ductwork ......................................................9
10 Return Air Filters .................................................. 10
11 Electric Heat .......................................................... 10
12 Electrical and Control Wiring............................... 12
12.1 Building Electrical Service Inspection .................. 12
12.2 Wire Sizing..........................................................12
12.3 Maximum Overcurrent Protection (MOP) ............12
12.4 Electrical Connections – Supply Voltage .............13
12.4.1 Air Handler Only (Non-Heat Kit Models) ....13
12.4.2 Air Handler - Non-Circuit Breaker Heat Kits .....13
12.4.3 Air Handler With Circuit Breaker Heat Kit.........13
12.5 Low Voltage Connections ....................................13
12.5.1 Thermostats ....................................................13
12.6 Speed Tap Adjustment.........................................13
13 Achieving 2% Low Leakage Rate ........................ 14
14 Start-Up Procedure ............................................... 14
15 Regular Maintenance............................................ 14
16 Airflow Data .......................................................... 15
21 Wiring Diagrams................................................... 21
IO-427K
10/2014
Question and Answer IconNeed help?

Do you have a question about the Goodman ARUF18B14 Series and is the answer not in the manual?

Goodman ARUF18B14 Series Specifications

General IconGeneral
ModelARUF18B14
Cooling Capacity1.5 Tons
CFM600
Width17.5 inches
Depth21 inches
RefrigerantR-410A
Motor TypePSC
Phase1
TypeAir Handler
Maximum Fuse Amperage15 Amps
Cabinet TypeFoil Faced

Summary

Important Safety Instructions

Carbon Monoxide Poisoning Hazard

Pre-Installation Considerations

Installation Preparation

Guidance on reading instructions, gathering tools, and ensuring all necessary items are available before installation.

System Matching Requirements

Specifies the need for manufacturer-approved and AHRI-listed system components to maintain warranty.

Installation Location

Upflow Installation

Instructions for upflow installation, including drip shield removal for optimal efficiency.

Horizontal Left Installation

Details for horizontal left installation, including primary drain connection and optional humidity kit.

Downflow and Horizontal Right Installation

Refrigerant Lines

Special Instructions for Refrigerant Expansion

Tubing Connections for Flowrator Model

Tubing Connections for TXV Models

Condensate Drain Lines

Electric Heat

Electrical and Control Wiring

Electrical Connections – Supply Voltage

Low Voltage Connections

Speed Tap Adjustment

Achieving 2% Low Leakage Rate

Start-Up Procedure

Air Handler Low Voltage Connections Diagrams

Single-Stage Cooling Wiring

Wiring diagram for single-stage cooling configurations with thermostat and condenser connections.

Heat Pump Wiring

Wiring diagrams for heat pump configurations, including thermostat, condenser, and outdoor thermostats.

ARUF/ARPT Wiring Diagrams

ASPT/ASUF Wiring Diagrams

3-Phase Heat Kit Wiring Diagram

Related product manuals