PRODUCT IDENTIFICATION
8
MODEL # MFG. # DESCRIPTION
AMH95
AMH95***AA
AMH95***AB
AMH95***AC
Amana® Brand 95% Gas Furnace, Upflow/Horizontal Left or Right, 40" tall, Induced Draft, new
two tone grey painted cabinet and front panels, standardized blower decks and a 120V Silicon
Nitride Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronic
ignition control and a Million-Air stainless steel tubular heat exchanger. NOx Certified. Chassis
sizes are now 17.5", 21" and 24.5" wide. Two stage heat, single stage cooling.
AMS95
AMS95***AA
AMS95***AB
Amana® Brand 95% Gas Furnace, Upflow/Horizontal Left and Right, 40" tall, Induced Draft, new
two tone grey painted cabinet and front panels, standardized blower decks and a Surestart Silicon
Nitride Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronic
ignition control and a Million-Air stainless steel tubular heat exchanger. NOx Certified. Chassis
sizes are now 17.5", 21" and 24.5" wide.
AMV9*
P1257401F,
P1257403F,
P1257405F
through
P1257406F
Amana® Brand 90% Variable Speed - 2 stage Gas Furnace, Upflow/Horizontal Left and Right,
40" tall, 2-stage Induced Draft, furnace redesign changes that include new two tone grey painted
cabinet and front panels, standardized blower decks and a Surestart Silicon Nitride Igniter. Left or
right gas pipe entry. The furnaces also feature an integrated electronic ignition control and a
Million-Air stainless steel tubular heat exchanger. NOx Certified. Chassis sizes are now 17.5", 21"
and 24.5" wide.
AMV9*
P1257407F,
P1257408F
Amana® Brand 90% Variable Speed - 2 stage Gas Furnace, Upflow/Horizontal Left and Right,
40" tall, 2-stage Induced Draft, furnace redesign changes that include new two tone grey painted
cabinet and front panels, standardized blower decks and a Surestart Silicon Nitride Igniter. Left or
right gas pipe entry. The furnaces also feature an integrated electronic ignition control and a
Million-Air stainless steel tubular heat exchanger. NOx Certified. Chassis sizes are now 17.5", 21"
and 24.5" wide.
(Note: The "P" numbers to the left include the following design changes.) Incorporates a
new crimped designed blower housing and a new blower deck. The crimped blower housing will
not fit inside of the previous "P" numbers for this same model. Redesigned 90° drain elbow by
adding a side drain port hole. The side port drain tube is only used when placing the furnace in
the horizontal left application.