11
PRODUCT DESIGN
Coil Matches (for Goodman
®
units using R22 and R-410A):
Product Type
C: Indoor Coil
C A P F 1824 A 6 A
Application
A: Upflow/Downflow Coil
H: Horizontal A Coil
S: Horizontal Slab Coil
Cabinet Finish
U: Uncased
P: Painted
C: Unpainted Case
Expansion Device
F: Flowrator
Nominal Capacity Range @ 13 SEER
1824: 1 1/2 to 2 Tons
3030: 2 1/2 Tons
3642: 3 to 3 1/2 Tons
4860: 4 & 5 Tons
Nominal Width for Gas Furnace
A: Fits 14" Furnace Cabinet
B: Fits 17 1/2" Furnace Cabinet
C: Fits 21" Furnace Cabinet
D: Fits 24 1/2" Furnace Cabinet
N: Does Not Apply (horizontal slab only)
6: R-22 or R-410A
2: R-22
4: R-410A
Refrigerant
Revision
A: Revision
Coil Matches:
A large array of Goodman
®
brand coils are available for use with the GMV95 & GCV9 model furnaces, in either
upflow or horizontal applications. These coils are available in both cased and uncased models, with or without
a TXV expansion device. These 90% - 95%+ furnaces match up with the existing Goodman
®
brand coils as
shown in the chart below.
• All CAPF coils in B, C, & D widths have insulated blank off plates for use with one size smaller furnaces.
• All CAPF coils have a CAUF equivalent.
• All CHPF coils in B, C & D heights have an insulated Z bracket for use with one size smaller furnace.
• All proper coil combinations are subject to being AHRI rated with a matched outdoor unit.