Service and Troubleshooting
*MVS96*U

Copyright © 2020 Goodman Manufacturing Company, L.P.
RS6612018r1
June 2020
TABLE OF CONTENTS
IMPORTANT INFORMATION ............................................ 2
PRODUCT IDENTIFICATION ........................................... 4
SYSTEM OPERATION ...................................................... 6
SCHEDULED MAINTENANCE ....................................... 21
SERVICING ..................................................................... 24
CHECKING VOLTAGE .............................................. 25
CHECKING WIRING .................................................. 25
CHECKNG THERMOSTAT, WIRING ........................ 25
CHECKING TRANSFORMER AND CONTROL
CIRCUIT ...................................................................... 25
CHECKING AIR CIRCULATOR BLOWER MOTOR 26
CHECKING DUCT STATIC ........................................ 26
CHECKING TEMPERATURE RISE .......................... 26
CHECKING PRIMARY LIMIT CONTROL ................. 27
CHECKING AUXILIARY LIMIT CONTROL ............... 27
INDUCED DRAFT BLOWER MOTOR ...................... 28
CECKING GAS VALVE (REDUNDANT) ................... 28
CHECKING GAS PRESSURE .................................. 28
CHECKING HOT SURFACE IGNITER ..................... 30
CHECKING PRESSURE TRANSDUCER ................ 30
CHECKING FOR DELAYED IGNITION .................... 31
CHECKING INTERGRATED IGNITION CONTROL
BOARDS ..................................................................... 31
CHECKING FLAME SENSOR ................................... 31
TROUBLESHOOTING CHART ....................................... 32
WIRING DIAGRAMS ....................................................... 39
Pride and workmanship go into every product to provide
our customers with quality products. It is possible, however,
that during its lifetime a product may require service.
Products should be serviced only by a qualied service
technician who is familiar with the safety procedures
required in the repair and who is equipped with the proper
tools, parts, testing instruments and the appropriate service
manual. 





















Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
0140M00517-A

Questions and Answers

  • M
    Michael TranAug 19, 2025
    What to do if my Goodman GMVS960805CU AA fails to operate due to excessive ignition retries?
    • M
      Mr. Joshua ZimmermanSep 12, 2025
      If your Goodman furnace fails to operate because of too many ignition retries, the possible causes are failure to establish flame, loss of flame after establishment, or gas interruption. You should locate and correct any gas interruption. Check the front cover pressure switch operation and ensure proper drainage, correcting if necessary. Consider replacing or realigning the igniter. Inspect the flame sense signal, cleaning the sensor if it's coated or oxidized. Verify the flue piping is free from blockages, has the correct length and elbows, and is properly terminated. Also, ensure the induced draft blower is performing as expected.
  • D
    Dylan FuentesAug 21, 2025
    What to do if my Goodman GMVS960805CU AA Furnace airflow is less than expected?
    • M
      Melissa TaylorAug 21, 2025
      If your Goodman furnace's airflow is less than expected, it might be operating in a power, temperature, or speed limiting condition. First, check the filters for any blockage and clean them or remove any obstructions. Next, inspect the ductwork for blockages and make sure all registers are fully open. Finally, verify that the ductwork is appropriately sized for the system; if not, resize or replace it as necessary.
  • R
    Ryan LittleAug 23, 2025
    Why my Goodman GMVS960805CU AA Furnace fails to operate and the integrated control module LED display provides no signal?
    • K
      Kathryn FisherAug 23, 2025
      If your Goodman furnace isn't working and the integrated control module LED display shows no signal, it could be due to a lack of 115V power to the furnace, no 24V power to the integrated control module, a blown fuse, a tripped circuit breaker, or a non-functional integrated control module. Restore high voltage power to the furnace and integrated control module. Replace the integrated control module if it's non-functional.
  • B
    brucewilsonAug 26, 2025
    What to do if my Goodman GMVS960805CU AA Furnace fails to operate because of grounding fault?
    • B
      Bradley PhelpsAug 26, 2025
      If your Goodman furnace fails to operate due to a grounding fault or poor neutral connection, verify the neutral wire connection to the furnace and confirm continuity to the ground source.
  • R
    Ryan BoydAug 27, 2025
    What to do if my Goodman furnace fails to operate because of an open roll out switch?
    • K
      Kristina BenitezAug 27, 2025
      If your Goodman furnace fails to operate due to an open roll out switch, check for correct gas pressure, correct burner alignment, and check for and correct any burner restrictions.
  • S
    Shawn TaylorAug 30, 2025
    What to do if my Goodman GMVS960805CU AA Furnace fails to operate and the circulator blower motor is not running?
    • M
      Mrs. Courtney Williams DDSAug 30, 2025
      If your Goodman furnace fails to operate because the circulator blower motor isn't running when it should be, check the wiring connections to ensure they are tight and correct. Verify there's a continuous circuit through the inductor, and replace it if it's open or short-circuited. Also, inspect the circulator blower motor itself and replace it if necessary.
  • C
    Courtney MarquezSep 1, 2025
    What to do if my Goodman GMVS960805CU AA fails to operate because of aux limit switch open?
    • A
      Anthony DominguezSep 1, 2025
      If your Goodman furnace fails to operate because the aux limit switch is open in the blower compartment, check the filters and ductwork for blockages. Clean the filters or remove any obstructions. Also, check the circulator blower speed and performance, correcting the speed or replacing the blower motor if necessary. Ensure that the wiring connections are tight and correct.
  • B
    Barry DiazSep 5, 2025
    What to do if my Goodman GMVS960805CU AA Furnace fails to operate because of a low stage pressure switch issue?
    • J
      James BurtonSep 5, 2025
      If your Goodman furnace fails to operate and it's due to the low stage pressure switch circuit being closed at the start of the heating cycle, the low stage pressure switch contacts sticking, or a short in the pressure switch circuit wiring, you should replace the low stage pressure switch or repair the short in the wiring.
  • T
    tcastilloSep 7, 2025
    What to do if my Goodman GMVS960805CU AA operation is different than expected because of invalid memory card data?
    • T
      tyrone53Sep 7, 2025
      If your Goodman furnace operation is different than expected due to invalid memory card data, verify the shared data set is correct for the specific model and re-populate the data using the correct memory card if required.
  • M
    Matthew VaughnSep 9, 2025
    What to do if my Goodman furnace fails to operate due to circulator blower motor communication loss?
    • B
      Brian HerreraSep 9, 2025
      If your Goodman furnace fails to operate because the integrated control module has lost communication with the circulator blower motor, tighten or correct the wiring connections. Check the circulator blower motor and replace if necessary. Also, check the integrated control module and replace it if needed.

Summary

Important Information

Important Notices for Consumers and Servicers

Essential safety notices and warnings for users and service personnel.

Recognize Safety Symbols, Words and Labels

Guidance on understanding safety symbols, words, and labels for hazard identification.

Product Identification

Nomenclature

Details on furnace model identification and component part naming conventions.

System Operation

Safety

Critical safety precautions to be followed during installation, adjustment, and operation.

24 Volt Thermostat Wiring

Instructions for connecting a 24-volt thermostat to the furnace control system.

CoolCloudHVAC Phone Application - General Information

Overview of the phone application for setup, diagnostics, and system adjustments.

Scheduled Maintenance

Annual Inspection

Recommended annual inspection checklist for ensuring proper furnace operation and safety.

Clocking a Gas Meter

Step-by-step guide to measuring the furnace's gas input rate using a gas meter.

Servicing

Component I.D.

Diagram identifying key components of the furnace for servicing.

Checking Voltage

Procedures for measuring and verifying electrical voltage levels within the furnace.

Checking Temperature Rise

Method for measuring and adjusting the temperature rise for optimal heat exchanger performance.

Checking Gas Pressure

How to measure and adjust gas supply and manifold pressures for correct operation.

Checking Flame Sensor

Testing the flame sensor for proper micro-amp signal and cleaning if necessary.

Troubleshooting

Menu Options

Description of various menu options available for furnace configuration and diagnostics.

Status Codes

List and description of LED display status codes for system diagnostics.

Fault Code Recall

How to access and interpret the last six fault codes detected by the furnace.

Wiring Diagrams

Goodman GMVS960805CU AA Specifications

General IconGeneral
ModelGMVS960805CU AA
TypeGas Furnace
Efficiency Rating96% AFUE
Heating Capacity80, 000 BTU