6 www.goodmanmfg.com SS-GMVM96
SS-GMVM96 www.goodmanmfg.com 7
Product SPecificationS
Product SPecificationS
GMVM96 airflow data — CooliNG speeds
GMVM960603BX GVMV960805CX
   
  CFM*   CFM*   CFM*   CFM*
A
Minus(-) 567
A
Minus(-) 351
A
Minus(-) 747
A
Minus(-) 486
Normal 630 Normal 390 Normal 830 Normal 540
Plus (+) 693 Plus (+) 429 Plus (+) 913 Plus (+) 594
B
Minus(-) 720
B
Minus(-) 495
B
Minus(-) 981
B
Minus(-) 675
Normal 800 Normal 550 Normal 1090 Normal 750
Plus (+) 880 Plus (+) 605 Plus (+) 1199 Plus (+) 825
C
Minus(-) 900
C
Minus(-) 612
C
Minus(-) 1314
C
Minus(-) 882
Normal 1000 Normal 680 Normal 1460 Normal 980
Plus (+) 1100 Plus (+) 748 Plus (+) 1606 Plus (+) 1078
D
Minus(-) 1089
D
Minus(-) 720
D
Minus(-) 1620
D
Minus(-) 1089
Normal 1210 Normal 800 Normal 1800 Normal 1210
Plus (+) 1331 Plus (+) 880 Plus (+) 1980 Plus (+) 1331
* @ .1" - .8" w.c. ESP * @ .1" - .8" w.c. ESP
GMVM961005DX GMVM961155DX
   
  CFM*   CFM*   CFM*   CFM*
A
Minus(-) 711
A
Minus(-) 459
A
Minus(-) 711
A
Minus(-) 459
Normal 790 Normal 510 Normal 790 Normal 510
Plus (+) 869 Plus (+) 561 Plus (+) 869 Plus (+) 561
B
Minus(-) 990
B
Minus(-) 639
B
Minus(-) 990
B
Minus(-) 639
Normal 1100 Normal 710 Normal 1100 Normal 710
Plus (+) 1210 Plus (+) 781 Plus (+) 1210 Plus (+) 781
C
Minus(-) 1269
C
Minus(-) 819
C
Minus(-) 1269
C
Minus(-) 819
Normal 1410 Normal 910 Normal 1410 Normal 910
Plus (+) 1551 Plus (+) 1001 Plus (+) 1551 Plus (+) 1001
D
Minus(-) 1647
D
Minus(-) 1044
D
Minus(-) 1647
D
Minus(-) 1044
Normal 1830 Normal 1160 Normal 1830 Normal 1160
Plus (+) 2013 Plus (+) 1276 Plus (+) 2013 Plus (+) 1276
* @ .1" - .8" w.c. ESP

 All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
 For most jobs, about 400 CFM per ton when cooling is desirable.
 