RS6100005
October 2007
Service
Instructions
Split System Wall Mounted
Air Conditioners and Heat Pumps
with R-410A Refrigerant
This manual is to be used by qualified, professionally trained HVAC technicians only.
Goodman does not assume any responsibility for property damage or personal injury due
to improper service procedures or services performed by an unqualified person.
Copyright © 2007 Goodman Manufacturing Company, L.P.
Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500
Houston, TX 77056
www.goodmanmfg.com
Question and Answer IconNeed help?

Do you have a question about the Goodman MSG-18CRN1N and is the answer not in the manual?

Summary

Important Information

General Service Guidelines

Guidance for qualified technicians; review all service info before repairs.

Safety Notices

Importance of safety symbols, words, and labels for proper understanding.

Important Information - Refrigerant Handling

Safe Refrigerant Handling

Safe handling practices for refrigerants, covering precautions and regulations.

Product Features

Indoor Unit Features

Lists features of the indoor unit, including controls, modes, and functions.

Outdoor Unit Features

Lists features of the outdoor unit, including control, design, and protection.

Product Design - Indoor Unit

Indoor Unit Dimensions

Provides dimensions for different indoor unit models in inches and millimeters.

Product Design - Outdoor Unit

Outdoor Unit Dimensions

Provides dimensions for different outdoor unit models in inches and millimeters.

Specifications - MSG-12 Models

MSG-12 CRN1 & MSG-12 HRN1 Specs

Detailed technical specifications for MSG-12CRN1 and MSG-12HRN1 models.

Specifications - MSG-18 Models

MSG-18 CRN1 & MSG-18 HRN1 Specs

Detailed technical specifications for MSG-18CRN1 and MSG-18HRN1 models.

Specifications - MSG-24 Models

MSG-24 CRN1 & MSG-24 HRN1 Specs

Detailed technical specifications for MSG-24CRN1 and MSG-24HRN1 models.

System Operation

Refrigerant Cycle Diagrams

Illustrates refrigerant flow in cooling-only and heat pump modes.

Operating Temperature Limits

Specifies the temperature ranges for cooling and heating operations.

Remote Control

Remote Control Performance Features

Explains performance features and button functions of the remote control.

Remote Display Panel Features

Describes the components and indicators on the remote control’s display panel.

Remote Control - Operation Details

Remote Display Indicators

Detailed explanation of each indicator on the remote display.

Automatic & Manual Operation Modes

Guide to setting up and using automatic and manual operation modes.

Service - Installation

Installation Requirements

Covers torque wrench, cable connection, and pipe length/elevation requirements.

Service - Evacuation

Evacuation Procedure

Step-by-step guide for evacuating the refrigerant system using a vacuum pump.

Service - Gas Charging

Gas Charging Procedure

Instructions for charging the system with R-410A refrigerant.

Service - Electronic Control

Electronic Control Functions & Specs

Lists functions and specifications of the electronic control system.

Service - Operation Modes

Protection Features & Modes

Details on protection features, fan modes, cooling, heating, and defrost operations.

Service - Special Operations

Special Operation Modes Explained

Explains forced cooling, sleep mode, auto restart, turbo mode, and display board indicators.

Troubleshooting - Display Errors

Display Board Error Indicators

Explains indicator lights for 12K and 18K/24K models during operation and faults.

Troubleshooting - 12 K Diagnostics

Diagnostic Chart for 12 k Models

Flowchart to diagnose issues when the unit does not operate after energizing.

Troubleshooting - 18 K;24 K Diagnostics

Diagnostic Chart for 18 k & 24 k Models

Flowchart to diagnose issues when the unit does not operate after energizing.

Troubleshooting - Control Board & Fan

Outdoor Control Board Resetting

Procedure to troubleshoot frequent resetting of the outdoor control board.

Indoor Fan Not Responding

Troubleshooting steps for the indoor fan when it is unresponsive.

Troubleshooting - Sensors & Compressor

Sensor and EEROM Errors

Diagnosis for temperature sensor errors and EEROM errors.

Compressor Overcurrent Protection

Troubleshooting steps for compressor overcurrent protection occurring multiple times.

Troubleshooting - Unit Operation

Outdoor Unit Operation Failure

Steps to diagnose why the outdoor unit fails to operate.

Indoor Unit Communication Error

Steps to diagnose communication errors between indoor and outdoor units.

Troubleshooting - Data

Temperature Sensor Data Table

Table mapping temperatures (°F/°C) to resistance values (kΩ) for sensors.

Wiring Diagrams - MSG-12 CRN1

MSG-12 CRN1 Indoor;Outdoor Wiring

Electrical schematic for the indoor and outdoor units of the MSG-12CRN1 model.

Wiring Diagrams - MSG-12 HRN1

MSG-12 HRN1 Indoor;Outdoor Wiring

Electrical schematic for the indoor and outdoor units of the MSG-12HRN1 model.

Wiring Diagrams - MSG-18;24 CRN1

MSG-18;24 CRN1 Indoor;Outdoor Wiring

Electrical schematics for the indoor and outdoor units of MSG-18CRN1 and MSG-24CRN1 models.

Wiring Diagrams - MSG-18;24 HRN1

MSG-18;24 HRN1 Indoor;Outdoor Wiring

Electrical schematics for the indoor and outdoor units of MSG-18HRN1 and MSG-24HRN1 models.

Summary

Important Information

General Service Guidelines

Guidance for qualified technicians; review all service info before repairs.

Safety Notices

Importance of safety symbols, words, and labels for proper understanding.

Important Information - Refrigerant Handling

Safe Refrigerant Handling

Safe handling practices for refrigerants, covering precautions and regulations.

Product Features

Indoor Unit Features

Lists features of the indoor unit, including controls, modes, and functions.

Outdoor Unit Features

Lists features of the outdoor unit, including control, design, and protection.

Product Design - Indoor Unit

Indoor Unit Dimensions

Provides dimensions for different indoor unit models in inches and millimeters.

Product Design - Outdoor Unit

Outdoor Unit Dimensions

Provides dimensions for different outdoor unit models in inches and millimeters.

Specifications - MSG-12 Models

MSG-12 CRN1 & MSG-12 HRN1 Specs

Detailed technical specifications for MSG-12CRN1 and MSG-12HRN1 models.

Specifications - MSG-18 Models

MSG-18 CRN1 & MSG-18 HRN1 Specs

Detailed technical specifications for MSG-18CRN1 and MSG-18HRN1 models.

Specifications - MSG-24 Models

MSG-24 CRN1 & MSG-24 HRN1 Specs

Detailed technical specifications for MSG-24CRN1 and MSG-24HRN1 models.

System Operation

Refrigerant Cycle Diagrams

Illustrates refrigerant flow in cooling-only and heat pump modes.

Operating Temperature Limits

Specifies the temperature ranges for cooling and heating operations.

Remote Control

Remote Control Performance Features

Explains performance features and button functions of the remote control.

Remote Display Panel Features

Describes the components and indicators on the remote control’s display panel.

Remote Control - Operation Details

Remote Display Indicators

Detailed explanation of each indicator on the remote display.

Automatic & Manual Operation Modes

Guide to setting up and using automatic and manual operation modes.

Service - Installation

Installation Requirements

Covers torque wrench, cable connection, and pipe length/elevation requirements.

Service - Evacuation

Evacuation Procedure

Step-by-step guide for evacuating the refrigerant system using a vacuum pump.

Service - Gas Charging

Gas Charging Procedure

Instructions for charging the system with R-410A refrigerant.

Service - Electronic Control

Electronic Control Functions & Specs

Lists functions and specifications of the electronic control system.

Service - Operation Modes

Protection Features & Modes

Details on protection features, fan modes, cooling, heating, and defrost operations.

Service - Special Operations

Special Operation Modes Explained

Explains forced cooling, sleep mode, auto restart, turbo mode, and display board indicators.

Troubleshooting - Display Errors

Display Board Error Indicators

Explains indicator lights for 12K and 18K/24K models during operation and faults.

Troubleshooting - 12 K Diagnostics

Diagnostic Chart for 12 k Models

Flowchart to diagnose issues when the unit does not operate after energizing.

Troubleshooting - 18 K;24 K Diagnostics

Diagnostic Chart for 18 k & 24 k Models

Flowchart to diagnose issues when the unit does not operate after energizing.

Troubleshooting - Control Board & Fan

Outdoor Control Board Resetting

Procedure to troubleshoot frequent resetting of the outdoor control board.

Indoor Fan Not Responding

Troubleshooting steps for the indoor fan when it is unresponsive.

Troubleshooting - Sensors & Compressor

Sensor and EEROM Errors

Diagnosis for temperature sensor errors and EEROM errors.

Compressor Overcurrent Protection

Troubleshooting steps for compressor overcurrent protection occurring multiple times.

Troubleshooting - Unit Operation

Outdoor Unit Operation Failure

Steps to diagnose why the outdoor unit fails to operate.

Indoor Unit Communication Error

Steps to diagnose communication errors between indoor and outdoor units.

Troubleshooting - Data

Temperature Sensor Data Table

Table mapping temperatures (°F/°C) to resistance values (kΩ) for sensors.

Wiring Diagrams - MSG-12 CRN1

MSG-12 CRN1 Indoor;Outdoor Wiring

Electrical schematic for the indoor and outdoor units of the MSG-12CRN1 model.

Wiring Diagrams - MSG-12 HRN1

MSG-12 HRN1 Indoor;Outdoor Wiring

Electrical schematic for the indoor and outdoor units of the MSG-12HRN1 model.

Wiring Diagrams - MSG-18;24 CRN1

MSG-18;24 CRN1 Indoor;Outdoor Wiring

Electrical schematics for the indoor and outdoor units of MSG-18CRN1 and MSG-24CRN1 models.

Wiring Diagrams - MSG-18;24 HRN1

MSG-18;24 HRN1 Indoor;Outdoor Wiring

Electrical schematics for the indoor and outdoor units of MSG-18HRN1 and MSG-24HRN1 models.

Goodman MSG-18CRN1N Specifications

General IconGeneral
ModelMSG-18CRN1N
RefrigerantR-410A
Voltage208/230 V
Phase1
Compressor TypeRotary
Cooling Capacity18000 BTU/h