835961-UIM-B-0412
Johnson Controls Unitary Products 9
TABLE 1:
R-410A Saturation Properties
Temp °F
Pressure
PSIG
Temp °F
Pressure
PSIG
Temp °F
Pressure
PSIG
Temp °F
Pressure
PSIG
Temp °F
Pressure
PSIG
45 130 60 170 75 217 90 274 105 341
46 132 61 173 76 221 91 278 106 345
47 135 62 176 77 224 92 282 107 350
48 137 63 179 78 228 93 287 108 355
49 140 64 182 79 232 94 291 109 360
50 142 65 185 80 235 95 295 110 365
51 145 66 188 81 239 96 299 111 370
52 147 67 191 82 243 97 304 112 375
53 150 68 194 83 247 98 308 113 380
54 153 69 197 84 250 99 313 114 385
55 156 70 201 85 254 100 317 115 391
56 158 71 204 86 258 101 322 116 396
57 161 72 207 87 262 102 326. 117 401
58 164 73 211 88 266 103 331 118 407
59 167 74 214 89 270 104 336 119 412
FIGURE 10: Heat Pump Flow Diagram
CHARGE COMPENSATOR
(Empty in cooling / full in heating)
(Not included in all Units)
FIELD CONNECTED LINE
INDOOR COIL
OUTDOOR
COIL
4-WAY
REVERSING
VALVE
FILTER DRYER
(Solid core)
SUCTION
ACCUMULATOR
LIQUID
SENSOR
COMPRESSOR
BI-FLOW
TXV/CHECK
VALVE (Cooling) **
BI-FLOW
TXV/CHECK
VALVE OR ORIFICE (Heating)
FIGURE 11: Time/Temp Control Module
90
30
60
Test
RUNTIME
MIN. SEL
REV
PRESSURE
COMP RLY
DFST
VA LVE
OM
XL
XL
R
R
C
C
Y
Y
O
O
W
W
W1/66
W1/66
PRESSURE
SWITCH
DFST
T’STAT
M
M
K2
K1
K3
R3
RUN TIME
30
90
TEST
TEST
RUN TIME
REV
COND.
FAN
ALTERNATE
CONFIGURATION
ALTERNATE
FIGURE 12: Demand Defrost Control Module
TEST
AMBIENT
AMBG
COIL G
COIL
1
2
3
4
COND
FAN
HIGH VOLTAGE
PRESSURE
M
SWITCH
REV
VALVE
X/L
R
C
Y
O
W
W1/66
X/L
R
C
Y
O
W
W1/66
DEMAND
DEFROST CURVE
SELECTION JUMPER
P