Model | GW5000-DNS-B30 |
---|---|
Rated Power | 5000 W |
Max. DC Input Power | 6500 W |
Max. PV Input Power | 6500 W |
Number of MPPT | 2 |
Max. Input Current per MPPT | 11 A |
Number of DC Inputs per MPPT | 1 |
Rated AC Output Power | 5000 W |
Max. AC Apparent Power | 5000 VA |
Max. Output Current | 22.7 A |
Rated AC Voltage | 230 V |
AC Voltage Range | 180 V - 280 V |
Rated Grid Frequency | 50 Hz / 60 Hz |
Total Harmonic Distortion (THDi) | < 3% |
DC Injection Current | < 0.5% In |
Max. Efficiency | 98.3% |
European Efficiency | 97.5% |
Protection Degree | IP65 |
Topology | Transformerless |
DC Switch | Yes |
Weight | 17 kg |
Cooling Method | Natural convection |
Number of MPPTs | 2 |
Protection Level | IP65 |
Power Factor | > 0.99 |
Operating Temperature Range | -25°C to +60°C |
Communication | RS485 |
Output Voltage | 230 V |
Output Frequency | 50 Hz / 60 Hz |
Operating Temperature | -25 ~ +60 °C |
Dimensions | 375 x 350 x 160 mm |
Provides essential safety rules and guidelines for operating the inverter.
Outlines safety precautions specific to the DC input connections.
Details safety measures for the AC output connections.
Covers crucial safety aspects related to the physical installation of the inverter.
Specifies the conditions and environment needed for proper installation.
Step-by-step instructions for physically mounting and installing the inverter.
Critical safety warnings before making any electrical connections.
Procedures for safely powering on the inverter.
Essential safety steps for powering down the inverter before maintenance.
Information and steps for diagnosing and resolving common inverter issues.