EasyManuals Logo

Goodwe NS Series User Manual

Goodwe NS Series
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
[1] For CEI 0-21 Nominal Output Power GW3000D-NS is 2700, GW3680D-NS is 3350, GW4200D-NS is 3800, GW5000D-NS is
4540, GW6000D-NS is 5450.
GW5000D-NS
6500
600
80~550
80~600
120
360
11/11
13.8/13.8
0
2
1
5000*
5000
220/230
50/60
21.7
<3%
97.8%
97.5%
GW6000D-NS
7200
600
80~550
80~600
120
360
11/11
13.8/13.8
0
2
1
6000*
6000
220/230
50/60
27.3
<3%
97.8%
97.5%
~1 (Adjustable from 0.8 leading to 0.8 lagging)
Technical Data
PV String Input Data
Max. DC Input Power (W)
Max. DC Input Voltage (V)
MPPT Range (V)
PV Input Operating Voltage Range
Start-up Voltage (V)
Nominal DC Input Voltage (V)
Max. Input Current (A)
Max. Short Current (A)
Maximum Inverter Backfeed Current to Array
No. of MPP Trackers
No. of Input Strings per Tracker
AC Output Data
Nominal Output Power (W) [1]
Max. Output Apparent Power (VA)
Nominal Output Voltage (V)
Nominal Output Frequency (Hz)
Max. Output Current (A)
Output Power Factor
Output THDi (@Nominal Output)
Efficiency
Max. Efficiency
Europe Efficiency
Protection
Anti-islanding Protection
Input Reverse Polarity Protection
Insulation Resistor Detection
Residual Current Monitoring Unit
Output Over Current Protection
Output Short Protection
Output Over Voltage Protection
Protective Class
General Data
Operating Temperature Range (℃)
Relative Humidity
Operating Altitude (m
Cooling
User Interface
Communication
Weight (kg)
Size (Width*Height*Depth mm
Protection Degree
The Decisive Voltage Class (DVC)
Night Self Consumption (W)
Topology
Certifications & Standards
Grid Regulation
Safety Regulation
EMC
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Protective Class I
-25~60
0~100%
≤4000
Natural Convection
LED(APP) or LCD
RS485 or WiFi
13
354*433*147
IP65
DVC-C
<1
Transformerless
Visit homepage to achieve information.
Moisture parameters
Temperature Range
Humidity Range
3K3
0~+40℃
5%~85%
4K2
-33~+40℃
15%~100%
4K4H
-20~+55℃
4%~100%
Level
Note:
Overvoltage Category Definition
Category I: applies to equipment connected to a circuit where measures have been taken to
reduce transient overvoltage to a low level.
Category II: applies to equipment not permanently connected to the installation. For example,
appliances, portable tools and other plug-connected equipment;
Category III: applies to fixed downstream equipment, including the main distribution board. For
example,switchgear and other equipment in an industrial installation;
Category IV: applies to equipment permanently connected at the origin of an installation
(upstream of the main distribution board).For example, electricity meters, primary
overcurrent protection equipment and other equipment connected directly to
outdoor open lines.
Moisture Location Category Definition
Environment Category Definition
Outdoor : the ambient air temperature is -20~50℃. Relative humidity range is from 4% to 100%,
applied to PD3.
Indoor unconditioned: the ambient air temperature is -20~50 ℃. Relative humidity range is from
5% to 95%, applied to PD3.
Indoor conditioned: the ambient air temperature is 0~40 ℃. Relative humidity range is from 5% to
85%, applied to PD2.
Pollution Degree Definition
Pollution degree 1: No pollution or only dry, non-conductive pollution occurs. The pollution has
no influence.
Pollution degree 2: Normally only non-conductive pollution occurs. However, a temporary
conductivity occasionally caused by condensation must be expected.
Pollution degree 3: Conductive pollution occurs. Or dry, non-conductive pollution becomes
conductive due to condensation, which is expected.
Pollution degree 4: Persistent conductive pollution occurs. For example, the pollution cause by
conductive dust, rain and snow.
3231

Other manuals for Goodwe NS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe NS Series and is the answer not in the manual?

Goodwe NS Series Specifications

General IconGeneral
Protection DegreeIP65
Number of MPP Trackers2
CoolingNatural Convection
Power Range3kW to 6kW
MPPTDual MPPT
CommunicationWiFi
MPPT Voltage Range120-500V
Nominal AC Output Power3000W to 6000W
Max. AC Output Power3.3kW, 4kW, 4.6kW, 5.5kW, 6.6kW
Nominal Output Voltage230V
Operating Temperature Range-25 ~ +60 °C
Output Power3000W to 6000W
MPPT Range120-500V
Output Voltage230V
Frequency50/60 Hz

Related product manuals