  • W
    watsondarrenSep 8, 2025
    What to do if Goodwe GW3600D-NS Inverter shows Relay-Check Failure?
    • N
      Nancy ColemanSep 8, 2025
      If your Goodwe Inverter is experiencing an Inverter Failure due to Relay-Check Failure, follow these steps: 1. Turn off the DC switch of the inverter. 2. Wait until the LCD light turns off. 3. Turn on the DC switch, ensuring it is properly connected. If the problem persists, contact your local service office for further assistance.
  • H
    henryfisherAug 25, 2025
    What causes Over Temperature error on Goodwe GW3600D-NS and how to fix it?
    • S
      sullivanjoanneAug 25, 2025
      The 'Over Temperature' error on your Goodwe Inverter indicates that the internal temperature is higher than normal. Try to decrease the ambient temperature or move the inverter to a cooler location.
  • S
    Samantha HillAug 25, 2025
    Why does my Goodwe GW3600D-NS Inverter show Utility Loss?
    • L
      Lauren TurnerAug 26, 2025
      A 'Utility Loss' message on your Goodwe Inverter indicates a disconnection from the power grid. Check if the power grid is connected to the cable and verify the availability of the power grid.
  • T
    Todd RussoSep 18, 2025
    What to do if my Goodwe Inverter displays GFCI Failure?
    • N
      Nina ThompsonSep 18, 2025
      If your Goodwe inverter displays a 'GFCI Failure', which indicates a current leakage test equipment failure, update the firmware to the latest version.
  • D
    dylan58Sep 8, 2025
    What to do if my Goodwe GW3600D-NS shows Utility Loss?
    • D
      Danielle RodriguezSep 9, 2025
      If your Goodwe Inverter indicates a Utility Loss, it means the inverter isn't detecting a grid connection. Here's what you should do: * Ensure the AC switch is in the ‘ON’ position. If it is, use a multimeter to check the voltage at the AC connector and the main switchboard wiring to confirm the grid is active. * Verify that the L, N, and PE wires are connected to the correct pins. Adjust the wiring if necessary. * Check the ‘Vac’ value displayed on the screen against the actual grid voltage. If the values are outside the regulation limits, contact your electricity company. * Turn off both the AC and DC power to the inverter, wait 5 minutes, and then measure the impedance between L & N to ground. If the values are less than 200KΩ, contact the GoodWe local service center.
  • T
    Tyler GilbertSep 13, 2025
    What causes Over Temperature Failure in Goodwe Inverter and how to resolve it?
    • M
      Mr. Joshua HubbardSep 13, 2025
      If your Goodwe Inverter is showing an Over Temperature Failure, it means the inverter is getting too hot. Here's what you can do: * Ensure the inverter is installed according to the user manual's guidelines for positioning and ventilation. * Try to lower the ambient temperature around the inverter. Shut it down for 15 minutes, then restart it. If the fault persists, contact a GoodWe service center.
  • T
    Tracey SandovalSep 3, 2025
    How to cool down my Goodwe Inverter if it shows 'Over Temperature'?
    • M
      Michael WalkerSep 3, 2025
      If your Goodwe inverter is showing an 'Over Temperature' warning, you can try the following: 1. Decrease the ambient temperature around the inverter. 2. Move the inverter to a cooler location.
  • J
    Johnny MacdonaldSep 4, 2025
    What to do if my Goodwe GW3600D-NS Inverter has Vac Failure?
    • E
      Erik SingletonSep 4, 2025
      If your Goodwe Inverter shows a Vac Failure, it could be due to several reasons: * The grid voltage might not be within the required specifications. * The neutral (N) wire and PE cable might not be properly connected. First, the PV Inverter will automatically restart within 5 minutes if the grid returns to normal. Ensure the grid voltage aligns with the specified requirements and that the neutral wire and PE cable are securely connected. If the issue persists, it may be necessary to seek assistance from a local service office.
  • S
    stevedavisSep 23, 2025
    What to do if my Goodwe GW3600D-NS is Over Temperature?
    • A
      Allison SanchezSep 23, 2025
      If your Goodwe Inverter is showing an 'Over Temperature' warning, it means the internal temperature is higher than the specified normal value. Try to reduce the ambient temperature and move the inverter to a cooler location. If the issue continues, contact your local service office.
  • A
    Ann WilsonAug 29, 2025
    What to do if my Goodwe GW3600D-NS shows 'Isolation Failure'?
    • Q
      qdavisAug 29, 2025
      If your Goodwe inverter displays an 'Isolation Failure', follow these steps: 1. Check the impedance between the ground and PV (+) & PV (-). The impedance value must be greater than 100kΩ. Ensure the inverter is properly grounded. 2. If the problem persists, contact your local service office for assistance. Additionally, the inverter has a built-in buzzer that will sound continuously for 1 minute upon failure. If the fault isn't resolved, the buzzer will sound every 30 minutes. You can also add the inverter to a monitoring platform and set up alarm reminders to receive email notifications about alarm information.

Summary

Product Introduction

Installation Guide

AC Terminals Connection

Instructions for connecting AC terminals to the inverter.

Booting-Up Process

Ezlogger Pro LAN: Setup Steps

Step-by-step instructions for setting up Ezlogger Pro LAN.

Trouble Shooting

Utility Loss Error

Troubleshooting steps for "Utility Loss" error code 23.

ISO Failure Error

Troubleshooting steps for "ISO Failure" error code 14.

Relay Check Failure Error

Troubleshooting steps for "Relay Check Failure" error code 07.

Ground I Failure Error

Troubleshooting steps for "Ground I Failure" error code 22/32.

Vac Failure Error

Troubleshooting steps for "Vac Failure" error code 09/10/12/15.

Fac Failure Error

Troubleshooting steps for "Fac Failure" error code 03/04/12.

PV Over Voltage Failure

Troubleshooting steps for "PV Over Voltage Failure" error code 17.

Over Temperature Failure

Troubleshooting steps for "Over Temperature Failure" error code 19.

AC HCT Failure Error

Troubleshooting steps for "AC HCT Failure" error code 31.

GFCI Failure Error

Troubleshooting steps for "GFCI Failure" error code 28/32.

Waiting Mode Error

Troubleshooting steps for inverter in "Waiting" mode.

Blank Screen Error

Troubleshooting steps for blank screen display.

WiFi Monitoring Failure

Troubleshooting steps for WiFi monitoring issues.

Technical Data

Warranty & Service

Warranty Conditions and Claims

Explains conditions and documentation needed for warranty claims.

Goodwe GW3600D-NS Specifications

General IconGeneral
BrandGoodwe
ModelGW3600D-NS
CategoryInverter
LanguageEnglish

Related product manuals