User Manual
Grid-Tied PV Inverter
SDT G2 Series
V1.0-2022-01-17

Other manuals for Goodwe GW6K-DT

Questions and Answers

  • P
    Patricia PowellSep 23, 2025
    What does IFan Fail mean on my Goodwe GW6K-DT Inverter?
    • J
      Jennifer GonzalezSep 23, 2025
      An IFan Fail error on your Goodwe Inverter indicates a fault in the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally.
  • A
    Ashley RamosAug 25, 2025
    How to fix an 'Over Temperature' error on my Goodwe GW6K-DT?
    • P
      pcareyAug 25, 2025
      If your Goodwe Inverter is showing an 'Over Temperature' error, there are a few things to check: 1. Ensure that the inverter has adequate ventilation and space for heat dissipation. 2. Verify that the ambient temperature is not too high. 3. Confirm that the fans are working correctly and are not blocked.
  • S
    Stacey LewisAug 25, 2025
    What to do if my Goodwe GW6K-DT Inverter displays 'Isolation Fail'?
    • J
      James FergusonAug 26, 2025
      If your Goodwe Inverter is showing an 'Isolation Fail' error, it could be due to: 1. A short circuit to the ground in the PV system. Check the PV input cables for any breaks. 2. A moist environment affecting the PV system's insulation. Ensure the module frames and metal bracket are securely grounded. 3. Also, check that the AC side is properly grounded.
  • M
    Matthew ReyesAug 27, 2025
    What does 'Vac Fail' mean on my Goodwe GW6K-DT Inverter?
    • R
      Renee MasonAug 27, 2025
      If your Goodwe Inverter shows 'Vac Fail', it means the utility grid voltage is out of the allowed range. Make sure that the grid voltage is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly.
  • A
    Andrew BrownAug 27, 2025
    What causes 'Fac Fail' on a Goodwe GW6K-DT?
    • T
      theresa70Aug 27, 2025
      If your Goodwe Inverter shows 'Fac Fail', it indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices under the same grid connection point is working normally, and whether the main supply is normal. Ensure the grid frequency is within the allowed range and that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly. If the fault happens occasionally, it may be due to instantaneous utility grid frequency change and does not need to be handled.
  • H
    Holly StoneSep 14, 2025
    What does ARC Fault mean on a Goodwe GW6K-DT, and how do I fix it?
    • M
      Michael DonaldsonSep 14, 2025
      An ARC Fault error on your Goodwe Inverter suggests that the PV string cables are arcing or are in poor contact. Check whether the PV terminals and cables are connected properly. Clear the error messages.
  • D
    Dennis CopelandSep 12, 2025
    What should I do if my Goodwe GW6K-DT Inverter displays a PV Over Voltage error?
    • K
      Kenneth RojasSep 12, 2025
      A PV Over Voltage error on your Goodwe Inverter can occur if excess PV modules are connected in series, causing the open-circuit voltage to be higher than the operating voltage. Check whether the PV string input voltage is consistent with the value displayed on the LCD and verify that the PV string voltage meets the maximum input voltage requirements.
  • S
    Stacey GreenSep 13, 2025
    Why does my Goodwe GW6K-DT show a Fac Fail error?
    • A
      Abigail FisherSep 13, 2025
      A Fac Fail error on your Goodwe Inverter indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices connected to the same grid connection point are working normally, and whether the main supply is normal. Make sure that the grid frequency is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly connected. Pay attention to the frequency of the fault. If it happens occasionally, the fault may be caused by the instantaneous utility grid frequency change and does not need to be handled.
  • L
    Lindsay ThompsonSep 5, 2025
    What does 'IFan Fail' mean on my Goodwe Inverter?
    • J
      Jason FigueroaSep 5, 2025
      If your Goodwe Inverter shows 'IFan Fail', it means there is a fault with the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally. For internal fan faults, contact after-sales service.
  • H
    huntfrederickSep 2, 2025
    What does 'DC Bus High' mean on my Goodwe GW6K-DT?
    • R
      Rhonda RamosSep 2, 2025
      If your Goodwe Inverter shows 'DC Bus High', it may indicate an internal fault. Ensure that the software version is the latest one. You can also try restarting the inverter to see if it resolves the issue.

Summary

2 Safety Precaution

2.1 General Safety

Provides essential safety guidelines for all operations.

2.2 DC Side

Outlines safety precautions specific to the DC connections.

2.3 AC Side

Details safety measures for AC connections.

2.4 Inverter Installation

Covers safety warnings related to inverter mounting and labels.

5 Installation

5.1 Installation Requirements

Specifies environmental, mounting, angle, and tool requirements for installation.

5.2 Inverter Installation

Covers procedures for moving and physically installing the inverter, including step-by-step mounting guides.

6 Electrical Connection

6.1 Safety Precautions

Critical safety guidelines before making electrical connections.

6.2 Connecting the PE Cable

Instructions for properly grounding the inverter.

6.3 Connecting the PV Input Cable

Guide for connecting PV strings to the inverter's DC input.

6.4 Connecting the AC Output Cable

Instructions for connecting the inverter to the AC grid.

7 Equipment Commissioning

8 System Commissioning

9 Maintenance

9.4 Troubleshooting

General guidance on diagnosing and resolving common inverter issues.

Goodwe GW6K-DT Specifications

General IconGeneral
ModelGW6K-DT
Rated Output Power6000 W
Max. DC Power9000 W
Max. PV Input Power9000 W
Number of MPPT Trackers2
Max. Input Current per MPPT13 A
Nominal AC Power6000 W
Max. AC Power6600 W
Nominal AC Voltage230 V
AC Output Voltage Range180-280V
Total Harmonic Distortion (THD)< 3%
DC Connection TypeMC4
Protection DegreeIP65
Max. Efficiency98.4%
Nominal Grid Frequency50 Hz
AC Output Frequency50 Hz
Power Factor0.8 leading - 0.8 lagging
AC Connection TypePlug
Operating Temperature Range-25°C to 60°C
Cooling MethodNatural convection
Dimensions370 mm x 470 mm x 160 mm