已发行

Questions and Answers

  • D
    Deborah OrtizAug 15, 2025
    What to do if my Goodwe GW3000-SS shows Utility Loss?
    • D
      Daniel JohnsonAug 15, 2025
      If your Goodwe Inverter shows a 'Utility Loss' error, it means the grid is not connected. First, check the grid connection cables and make sure they are properly connected. Then, verify the grid's usability to ensure it is functioning correctly.
  • N
    Nathaniel MannAug 18, 2025
    How to fix Over Temperature error on Goodwe Inverter?
    • A
      andrewgilmoreAug 18, 2025
      If your Goodwe inverter is showing an 'Over Temperature' error, it means the internal temperature is higher than the normal specified value. To resolve this: * Reduce the ambient temperature around the inverter. * Move the inverter to a cooler location. If the issue persists, further assistance may be needed.
  • C
    Christina MillerAug 21, 2025
    What to do if Goodwe GW3000-SS Inverter shows Ground I Failure?
    • C
      christophercarterAug 21, 2025
      If your Goodwe Inverter displays a 'Ground I Failure', it indicates that the ground current is too high. Unplug the inputs from the PV generator and check the peripheral AC system. When the problem is cleared, reconnect the PV panel and check the inverter status.
  • H
    huntdorisAug 25, 2025
    How to troubleshoot Isolation Failure on a Goodwe GW3000-SS Inverter?
    • N
      Natalie CarlsonAug 25, 2025
      To address an 'Isolation Failure' on your Goodwe Inverter, check the impedance between PV (+) & PV (-) and ensure the PV inverter is earthed. The impedance value must be greater than 2M?. If the problem persists, further assistance may be needed.
  • A
    Alisha PetersenAug 27, 2025
    What causes PV Over Voltage on a Goodwe GW3000-SS?
    • M
      Michael JonesAug 27, 2025
      If your Goodwe Inverter is showing a 'PV Over Voltage' error, check whether the PV open voltage is higher or too close to the maximum input voltage. If the problem still exists when the PV voltage is less than the maximum input voltage, further assistance may be needed.
  • R
    rodney96Aug 30, 2025
    What to do if my Goodwe GW3000-SS Inverter has Vac Failure?
    • D
      David JohnsonAug 30, 2025
      If your Goodwe Inverter shows a 'Vac Failure', the PV Inverter will automatically restart within 5 minutes if the grid returns to normal. Also, make sure grid voltage conforms with the specification. If the problem still exists, further assistance may be needed.
  • C
    crobertsSep 2, 2025
    What does Fac Failure mean on a Goodwe GW3000-SS Inverter?
    • A
      Angela BerrySep 2, 2025
      If your Goodwe Inverter displays a 'Fac Failure', the PV Inverter will automatically restart within 5 minutes if the grid returns to normal. Also, make sure grid frequency is in conformity with the specification. If the problem still exists, further assistance may be needed.
  • V
    Victoria BoyerSep 5, 2025
    How to resolve Consistent Failure on a Goodwe Inverter?
    • M
      michele47Sep 5, 2025
      If your Goodwe Inverter is experiencing a 'Consistent Failure', disconnect PV (+) or PV (-) from the input and restart the PV Inverter. If the problem still exists, further assistance may be needed.
  • J
    Joseph MorganSep 8, 2025
    What to do for Relay-Check Failure on Goodwe GW3000-SS?
    • D
      Deborah WilliamsonSep 8, 2025
      To address a 'Relay-Check Failure' on your Goodwe Inverter: 1. Disconnect all PV (+) or PV (-). 2. Wait for a few seconds. 3. After the LCD switches off, reconnect and check again. If the message appears again, further assistance may be needed.
  • J
    James ToddSep 12, 2025
    Why does my Goodwe GW3000-SS Inverter shut down with Insufficient sunlight?
    • M
      myersabigailSep 12, 2025
      When sunlight is insufficient, the Goodwe PV Inverter may continuously start up and shut down automatically due to insufficient power generated by the PV panel. If the problem remains, further assistance may be needed.

Summary

1 Symbols

2 Safety

3 Installation

3.1 Mounting Instruction

Guidance on optimal placement and installation of the inverter for performance and maintenance.

3.2 Unpacking

Instructions for checking the inverter and its accessories upon receipt.

3.3 Equipment Installation

3.3.2 Mounting Procedure

Step-by-step guide for physically mounting the inverter onto a wall.

3.4 Electrical Connection

3.4.2 DC side connection

Guidelines for connecting the DC input from PV panels to the inverter.

3.4.3 RS485 Communication

Details on connecting the inverter using the RS485 interface for communication.

3.4.4 Wireless Communication

Information on setting up wireless communication for the inverter.

3.4.5 WiFi Communication

Procedure for configuring and using the inverter's WiFi connectivity.

Step2: Registration

Step3: Create PV Station

3.4.6 Communication with Solar-Log Device

3.4.7 USB Communication

3.5 Troubleshooting

4 System Operation

4.1 Operating Panel

Overview of the inverter's physical controls and indicator lights.

4.2 Indicator Lights

Explanation of the status indicated by the LED lights on the inverter.

4.3 LCD Display

Detailed explanation of the inverter's LCD screen elements and information.

4.4 Error messages

List and description of error messages displayed by the inverter.

4.5 ID RESET

Procedure for resetting the inverter's wireless ID to resolve connection issues.

5 Technical Parameters

6 Certificates

7 Warranty

7.1 Warranty Period

Details on the standard 5-year warranty period for SS series products.

7.2 Warranty Card

Instructions for keeping the warranty card and purchase invoice for service.

7.3 Warranty Conditions

Conditions for product maintenance, repair, or replacement under warranty.

7.4 Scope of Warranty

Situations where the product warranty is considered invalid.

8 Contact

Goodwe GW3000-SS Specifications

General IconGeneral
ModelGW3000-SS
Rated Power Output3000 W
Max. PV Input Power4500 W
Start Voltage120V
Number of MPP Trackers1
Max. Input Current per MPPT11 A
Max. Input Current11 A
Rated AC Output Power3000 W
Max. AC Apparent Power3000 VA
Rated AC Voltage230 V
Rated Grid Frequency50Hz/60Hz
Total Harmonic Distortion (THD)< 3%
Power Factor>0.99
Protection DegreeIP65
Cooling MethodNatural Cooling
AC Voltage Range180V-280V
Operating Temperature Range-25 °C to +60 °C
Max. AC Output Current14 A
DC Injection Current<0.5% of rated output current