User Manual
GOODWE SS SERIES
Ver 02
已发行

Questions and Answers

  • J
    Jeffrey WilliamsonAug 15, 2025
    What to do if my Goodwe Inverter shows Utility Loss?
    • J
      Joseph HarrisAug 15, 2025
      If your Goodwe Inverter shows a 'Utility Loss' error, it means the grid is not connected. First, check the grid connection cables and make sure they are properly connected. Then, verify the grid's usability to ensure it is functioning correctly.
  • H
    Hannah CooperAug 18, 2025
    How to fix Over Temperature error on Goodwe Inverter?
    • O
      Olivia RamirezAug 19, 2025
      If your Goodwe inverter is showing an 'Over Temperature' error, it means the internal temperature is higher than the normal specified value. To resolve this: * Reduce the ambient temperature around the inverter. * Move the inverter to a cooler location. If the issue persists, further assistance may be needed.
  • C
    Christopher WeissAug 21, 2025
    What to do if Goodwe Inverter shows Ground I Failure?
    • A
      Amber VasquezAug 21, 2025
      If your Goodwe Inverter displays a 'Ground I Failure', it indicates that the ground current is too high. Unplug the inputs from the PV generator and check the peripheral AC system. When the problem is cleared, reconnect the PV panel and check the inverter status.
  • A
    Angela JohnsonAug 25, 2025
    How to troubleshoot Isolation Failure on a Goodwe GW3600S-UK?
    • L
      Larry GardnerAug 25, 2025
      To address an 'Isolation Failure' on your Goodwe Inverter, check the impedance between PV (+) & PV (-) and ensure the PV inverter is earthed. The impedance value must be greater than 2M?. If the problem persists, further assistance may be needed.
  • W
    William MorseAug 28, 2025
    What causes PV Over Voltage on a Goodwe GW3600S-UK?
    • K
      Kathy ParksAug 28, 2025
      If your Goodwe Inverter is showing a 'PV Over Voltage' error, check whether the PV open voltage is higher or too close to the maximum input voltage. If the problem still exists when the PV voltage is less than the maximum input voltage, further assistance may be needed.
  • B
    Brenda EvansAug 30, 2025
    What to do if my Goodwe GW3600S-UK has Vac Failure?
    • K
      Kelly VaughanAug 30, 2025
      If your Goodwe Inverter shows a 'Vac Failure', the PV Inverter will automatically restart within 5 minutes if the grid returns to normal. Also, make sure grid voltage conforms with the specification. If the problem still exists, further assistance may be needed.
  • C
    Christopher MooreSep 2, 2025
    What does Fac Failure mean on a Goodwe GW3600S-UK Inverter?
    • M
      Melissa HernandezSep 2, 2025
      If your Goodwe Inverter displays a 'Fac Failure', the PV Inverter will automatically restart within 5 minutes if the grid returns to normal. Also, make sure grid frequency is in conformity with the specification. If the problem still exists, further assistance may be needed.
  • E
    Eric ReillySep 5, 2025
    How to resolve Consistent Failure on a Goodwe GW3600S-UK?
    • M
      Manuel RussellSep 6, 2025
      If your Goodwe Inverter is experiencing a 'Consistent Failure', disconnect PV (+) or PV (-) from the input and restart the PV Inverter. If the problem still exists, further assistance may be needed.
  • J
    Jeffery CruzSep 8, 2025
    What to do for Relay-Check Failure on Goodwe GW3600S-UK?
    • S
      Samuel HollowaySep 9, 2025
      To address a 'Relay-Check Failure' on your Goodwe Inverter: 1. Disconnect all PV (+) or PV (-). 2. Wait for a few seconds. 3. After the LCD switches off, reconnect and check again. If the message appears again, further assistance may be needed.
  • T
    Troy DeckerSep 12, 2025
    Why does my Goodwe GW3600S-UK shut down with Insufficient sunlight?
    • M
      Mark DixonSep 12, 2025
      When sunlight is insufficient, the Goodwe PV Inverter may continuously start up and shut down automatically due to insufficient power generated by the PV panel. If the problem remains, further assistance may be needed.

Summary

1 Symbols

Explanation of Symbols

Explanation of various symbols used throughout the manual for warnings and information.

2 Safety

Safety Guidelines and Precautions

Essential safety guidelines and precautions for operating and installing the inverter.

3 Installation

3.1 Mounting Instruction

Instructions for correctly mounting the inverter for optimal performance.

3.2 Unpacking

Check for external damage and verify all included accessories upon receiving the inverter.

3.3 Equipment Installation

Detailed steps for installing the inverter unit, including position selection.

3.4 Electrical Connection

Guidelines for making AC and DC electrical connections to the inverter.

3.5 Troubleshooting

Troubleshooting Common Issues

Guidance on diagnosing and resolving common issues and error messages.

4 System Operation

4.1 Operating Panel

Description of the inverter's front panel indicators and their meanings.

4.2 Indicator Lights

Explanation of the status indicated by the yellow, green, and red indicator lights.

4.3 LCD Display

Details on the inverter's LCD screen layout, display areas, and information shown.

4.4 Error messages

List of error messages displayed by the inverter and their descriptions.

4.5 ID RESET

Procedure for resetting the inverter's wireless monitoring ID.

5 Technical Parameters

Model Specifications

Specifications and performance data for various GoodWe inverter models.

6 Certificates

Product Certifications

List of certifications and approvals obtained by the inverter.

7 Warranty

7.1 Warranty Period

Details on the standard warranty duration for SS series products.

7.2 Warranty Card

Requirements for keeping the warranty card and product nameplate visible.

7.3 Warranty Conditions

Conditions under which the inverter will be maintained, repaired, or replaced.

7.4 Scope of Warranty

Situations where the product warranty is considered invalid.

8 Contact

Customer Service Contact

Contact information for customer service and technical support for GoodWe SS series inverters.

Goodwe GW3600S-UK Specifications

General IconGeneral
ModelGW3600S-UK
Rated Power3600 W
Rated AC Output Power3600 W
Max. AC Apparent Power3600 VA
Max. Output Current16 A
Rated Output Voltage230 V
Max. Efficiency97.6 %
MPPT Number2
DC Input Number2
Max. Input Current11 A
Number of MPP Trackers2
Output Frequency50/60Hz
CoolingNatural convection
Protection DegreeIP65
Protection ClassClass I
Warranty5 years
AC Voltage Range180~280V
Operating Temperature-25°C to 60°C