Crucial safety warning stating the instrument must be operated under the supervision of a qualified electrician.
Details the primary applications of the PROFITEST 204+ for electrical and electronic equipment testing.
Essential safety rules for operating the instrument, including power connection and handling unexpected voltages.
Precautions to prevent unauthorized and unintentional activation, plus general safety measures.
Essential warnings regarding direct contact with high-voltage probes and devices during testing.
Procedure for connecting the PROFITEST 204+ to a 230 V mains power supply.
Instructions for connecting the high-voltage module to the basic unit or directly to mains power.
Steps for conducting the self-test and understanding the displayed results and error messages.
Introduction to the protective conductor test, its purpose, and the required test current.
Information regarding test parameter settings and limit values according to DIN VDE standards.
Guide to adapting test duration and setting limit values for protective conductor resistance.
Steps to initiate the protective conductor test from the parameters window and save events.
Detailed steps for measuring insulation resistance, including safety warnings and cable checks.
How to select test voltage and set the limit value for insulation resistance measurements.
Guide to changing the limit value for leakage current measurements.
Steps to initiate the leakage current test, including safety precautions regarding voltage.
Procedure for measuring voltage and discharge time, ensuring residual voltage drops below 60V within 5 seconds.
How to configure the maximum permissible discharge period for voltage measurements.
Details on using the optional PROFITEST 204HP/HV module and the test voltage requirements.
Performing a preliminary functions test for the high-voltage test, covering key switch and signal lamps.
Procedures for shutting down the high-voltage test and understanding the final displayed values and symbols.
Guide to configuring test duration, test voltage, and maximum allowable current (IMAX) for high-voltage tests.
Details on setting up parameters like duration, test voltage, and rise time for high-voltage tests.
Step-by-step guide for performing the high-voltage test, emphasizing safety and correct probe contact.
How to select, describe, and manage measurement systems within the instrument's data management.
Introduction to data transmission between instrument and PC, including the use of WinProfi software.
Table detailing measurement ranges, nominal voltages, and uncertainties for various tests performed by the PROFITEST 204+.
Specific measurement ranges, uncertainties for PROFITEST 204HP and 204HP-2.5kV models.
Specific measurement ranges, uncertainties for PROFITEST 204HV and 204HV-5.4kV models.
Table of adjustable parameter ranges and standard values per DIN VDE for the PROFITEST 204+.
Guidance on selecting protective conductor test limit values based on overvoltage protection device characteristics.
Information on the RS 232 interface, its protocol, technical data, and connector pin assignments.
Table detailing signals, error messages, their causes, and remedies for the PROFITEST 204+ basic instrument.
Messages related to high-voltage module detection, signal lamp failures, and faulty data exchange.
Instructions for safely replacing mains and test probe fuses, emphasizing the use of specified original fuses.