OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
12
Page
CFC-free refrigerant R134a / CFC-free refrigerant R452A
N = Normal refrigeration
N/T = Normal refrigeration at high outside temperature
P = Polytemperature
K = Climate heater (ensuring the desired temperature in winter)
The refrigeration capacity is based on the following operating
conditions: Outside temperature 30 °C, RH 50% / * Outside
temperature 40 °C, RH 50%
We recommend an insulation with a k value of 0.2 W/m²K
Tab. 3-1 Technical data
Description Unit
arktik
1600N
arktik
1600N/T
arktik
2000N
arktik
2500N
arktik
2500N/K
arktik
2000P
arktik
2000P/K
Refrigerated trailer
internal temperature
°C T=2°C T=2°C T=2°C T=2°C T=2°C
T=2 °C/
-20 °C
T=2 °C/
-20 °C
Power supply
V 230 230 230 230 230 230 230
Frequency
Hz 50 50 50 50 50 50 50
Cooling capacity
W 1600 1470* 2050 2500 2500 2050/1500 2050/1500
Heating capacity
W -/- -/- -/- -/- 1600 -/- 1600
Power consuption
W 855 855 1260 1200 1200 1200/1000 1200/1000
Current
consumption LRA
A 19,8 19,8 29 32 32 32 32
Current
consumption FLA
A 4,8 4,8 5,7 7 7 7,0/6,5 7,0/6,5
Defrosting
W 340 340 340 600 600 1230 1230
Air flow evaporator
m3/h 750 750 750 1100 1100 1100 1100
Air flow condenser
m3/h 750 1100 1100 1100 1100 1100 1100
Protection class,
mounting side
IP 54 54 54 54 54 54 54
Refrigerant
Typ R134a R134a R134a R452A R452A R452A R452A
Refrigerant
quantity
g 450 450 550 800 800 1170 1170
Max. operating
temperature
°C 40 45 40 40 40 40 40
Weight
kg 55 55 63 63 63 63 63
Colour
RAL 9010 9010 9010 9010 9010 9010 9010