OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
6
Page
2.3 Safety and Hazard Precautions
WARNING!
Electrical hazard!
Any work on the trailer refrigeration unit is allowed with
unplugged main plug only.
Protect the trailer refrigeration unit against being started up while
working on it by following suitable measures.
Never attempt to plug in or unplug the trailer refrigeration unit from the
power supply when your hands are wet.
WARNING!
Electrical hazard!
The following safety rules must be strictly observed before working on
the trailer refrigeration unit:
• Switch o.
• Prevent it from being switched back on again accidentally.
• Check that lines and equipment are without power.
• Ground and short circuit phases.
• Cover, partition or screen of adjacent line sections.
The electrical connection to the trailer refrigeration unit must be made
by a licensed electrician.
WARNING!
Hazard from toxic gas!
Thisrefrigerationunitcontainsauorocarbonrefrigerant,which,inthe
presenceofanopenameorelectricalshort,producestoxicgases
that are severe respiratory irritants capable of causing death.
The refrigerant tends to displace air and can cause oxygen depletion,
whichmayresultindeathbysuocation.
Be careful when working on the trailer refrigeration unit,
especially in any enclosed or conned area with a limited air
supply!
WARNING!
Fire and explosion hazard from ammable operating materials!
Avoidopenre,electricalsparksandignitionsources.
Do not smoke!
Observemeasuresforreandexplosionprotection.