OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
28
Page
Maintain the trailer refrigeration unit
• every 6 months, or
• after a longer period out of operation or
• immediately after operation in a dusty or moist environment.
Negligent maintenance can lead to malfunction and damage the
trailer refrigeration unit.
10.1 Manual Defrost During Maintenance
See section 9.4. Manual Defrost During Maintenance
10.2 Cleaning
10.2.1 Cleaning Parts Inside the Refrigeration Unit
WARNING!
Fire and explosion hazard!
Never use ammable solvents such as alcohol, benzene or
thinners for cleaning.
1. Clear the refrigeration unit of all goods and merchandise.
2. Disconnect the trailer refrigeration unit from the power supply by
pulling the main plug.
3. Clean the evaporator by applying compressed air from an
appropriate distance.
4. Connect again the trailer refrigeration unit to the power supply by
inserting the main plug.
Fig. 10-1 Cleaning parts
inside the refrigeration unit
1
1. Evaporator