L5
Limit switches
polarity
Normally open
nc
Normally close
ex
L5 LIMIT SWITCHES POLARITY - Set if L5 are NO or NC. Use up/down to choose NO (NO), NC (NC) or EXIT (EX).
Pr
Motor power in fast
speed
0 - 10
ex
EXIT or push together
PR MOTOR POWER IN FAST SPEED - Set the motor power (fast speed) between 1 (10%) and 10 (100%).
pl
Motor power in
slowing down
0 - 10
Pl MOTOR POWER IN SLOWING DOWN - Set the motor power (slowing down) between 1 (10%) and 10 (100%).
55
Soft start
Y5
Enabled
Nt
Disabled
EXIT or push together
55 SOFT START - Set if soft start is active (Y5) or not (NT). Soft start make a linear power slope to avoid mech
bl
Blinker mode
Y5
Nt
Disable blinking (for flashing lights equipped
with a flashing board)
ex
EXIT or push together
BL BLINKER MODE - Set if blinker output works as blinker, or as semaphore signal. Use up/down to choose
blinker mode (Y5), Semaphore mode (NT) or exit (EX). Push ENTER to confirm.
cr
(Aux) Courtesy light
mode
Y5
ex
EXIT or push together
cr (AUX) COURTESY LIGHT MODE - Set if AUX dry contact works as courtesy light or as blinker. Use up/down to
choose courtesy light mode (Y5), Blinker mode (NT) or exit (EX). Push enter to confirm.
D2
Load defaults
Y5
Enabled
ex
EXIT or push together
D2 LOAD FACTORY SETTINGS - To reset the control unit to factory conditions, select this menu and then confirm
rc
Release torque at the
end of closing
Y5
Enabled
Nt
ex
EXIT or push together
RC RELEASE AT END OF CLOSING - By activating this function (Y5) the motor will perform a brief inversion at the
end of closing, in order to release the mechanical tension.