Installation and Operation
Fire-Ball
®
225, 300, and 425 Oil Pumps
For non-corrosive and non-abrasive oils
and lubricants only.
Mini Fire-Ball 225, 3:1
Parts 246775 and 248097
540 psi (3.7 MPa, 37 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Fire-Ball 300, 5:1
Parts 203876, 203872, 203857, 204254, and 222087
900 psi (6.2 MPa, 62 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Fire-Ball 425, 10:1
Parts 205626, 222065, and 222095
1800 psi (12.4 MPa, 124 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
309868 rev.B

Other manuals for Graco 205626

Questions and Answers

  • D
    Dr. Joshua Griffin MDSep 23, 2025
    What to do if Graco Water Pump output is low on up stroke?
    • E
      Eric McdonaldSep 23, 2025
      If your Graco Water Pump operates, but the output is low on the up stroke, it could be due to held open or worn piston packings that need to be cleared or serviced.
  • A
    Ashley RossAug 31, 2025
    What to do if Graco 205626 operates, but output is low on upstroke?
    • D
      dperryAug 31, 2025
      If your Graco Water Pump operates, but the output is low on the upstroke, it could be due to held open or worn piston or packings. Clear any obstructions and service the pump.
  • C
    Christopher FreemanAug 25, 2025
    Why does my Graco 205626 Water Pump fail to operate?
    • W
      William CookAug 25, 2025
      If your Graco Water Pump fails to operate, several factors could be at play. Start by checking the air supply pressure to ensure it's adequate and that the air lines aren't restricted; increase the air supply and clear any obstructions. Also, make sure that valves are open and not clogged; open or clean them as needed. Clear any clogs from fluid lines, hoses, and valves. If the fluid supply is exhausted, refill and reprime, or flush the system. If these steps don't resolve the issue, the air motor might be damaged and require servicing.
  • L
    Luis BennettAug 25, 2025
    What to do if Graco 205626 operates, but output low on both strokes?
    • B
      Brenda JacksonAug 26, 2025
      If your Graco Water Pump operates, but the output is low on both strokes, there might be several reasons. First, check if the air supply is adequate and the air lines are not restricted; increase the air supply and clear any obstructions. Next, ensure that the valves are open and not clogged; open or clean them as needed. If the fluid supply is exhausted, refill and reprime, or flush the system. Also, clear any clogs from fluid lines, hoses, and valves. Finally, check for loose packing nuts or worn packings; tighten or replace them as necessary.
  • E
    erinmillerAug 26, 2025
    Why is my Graco Water Pump operation erratic?
    • B
      bbennettAug 26, 2025
      If the Graco Water Pump is experiencing erratic operation, it could be due to a couple of reasons. Check if the fluid supply is exhausted; if so, refill and reprime, or flush the system. Additionally, inspect the intake valve or piston packings for being held open or worn; clear any obstructions and service as needed.
  • G
    Glen ManningAug 27, 2025
    Why is there continuous air exhaust from my Graco 205626 Water Pump?
    • N
      nbakerAug 27, 2025
      Continuous air exhaust in your Graco Water Pump usually indicates a problem within the air motor. Specifically, it suggests that the air motor gasket, packing, seal, or a similar component is worn or damaged. To resolve this, you'll need to service the air motor.
  • R
    Robin CampbellAug 27, 2025
    What to do if Graco 205626 operates, but output low on upstroke?
    • J
      jacob92Aug 27, 2025
      If your Graco Water Pump operates, but the output is low on the upstroke, it could be due to a held open or worn piston or packings. Clear any obstructions and service as needed.
  • L
    Lauren WilsonAug 28, 2025
    What to do if Graco 205626 Water Pump operates, but output low on downstroke?
    • W
      willie30Aug 28, 2025
      If your Graco Water Pump operates, but the output is low on the downstroke, it could be due to a held open or worn intake valve. Clear any obstructions and service as needed.
  • R
    raymondboothAug 28, 2025
    Why is my Graco 205626 Water Pump not operating?
    • T
      Tom HensonAug 28, 2025
      Your Graco Water Pump might fail to operate due to several reasons: * Inadequate air supply pressure or restricted air lines. Solution: Increase air supply and clear any obstructions. * Closed or clogged valves. Solution: Open and clean the valves. * Clogged fluid lines, hoses or valves. Solution: Clear any blockages. * Damaged air motor. Solution: Service the air motor. * Exhausted fluid supply. Solution: Refill and reprime, or flush the pump.
  • I
    Isaac BatesAug 29, 2025
    What to do if Graco 205626 operates, but output is low on both strokes?
    • G
      Gerald JohnsonAug 29, 2025
      If your Graco Water Pump operates, but the output is low on both strokes, the issue could be due to: * Inadequate air supply or restricted air lines. Increase the air supply and clear any obstructions. * Closed or clogged valves. Open and clean the valves. * Exhausted fluid supply. Refill and reprime, or flush the pump. * Clogged fluid lines, hoses, valves, etc. Clear any blockages. * Packing nut too tight. Loosen the packing nut. * Loose packing nut or worn packings. Tighten or replace the packings.

Graco 205626 Specifications

General IconGeneral
Model Number205626
Power SourceAir
TypeDiaphragm Pump
Maximum Working Pressure100 psi (0.7 MPa, 7 bar)
Air Inlet Size1/4 in npt(f)
Fluid Inlet Size1/2" NPT
Fluid Outlet Size1/2" NPT
Wetted PartsPolypropylene, Santoprene
Maximum Pressure100 psi
Inlet Size1/2" NPT
Outlet Size1/2" NPT