Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
Copyright 2004, Graco Inc. is registered to I.S. EN ISO 9001
Installation and Operation
Fire-Ball
®
225, 300, and 425 Oil Pumps
For non-corrosive and non-abrasive oils
and lubricants only.
Mini Fire-Ball 225, 3:1
Parts 246775 and 248097
540 psi (3.7 MPa, 37 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Fire-Ball 300, 5:1
Parts 203876, 203872, 203857, 204254, and 222087
900 psi (6.2 MPa, 62 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Fire-Ball 425, 10:1
Parts 205626, 222065, and 222095
1800 psi (12.4 MPa, 124 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
309868 rev.B

Other manuals for Graco 205626

Questions and Answers

  • T
    Tiffany BanksAug 30, 2025
    Why is my Graco 205626 Water Pump air continuously exhausting?
    • S
      Sara SalinasAug 30, 2025
      Continuous air exhaust from your Graco Water Pump is likely due to a worn or damaged air motor gasket, packing, seal, etc. The solution is to service the air motor.
  • K
    Kevin GarciaAug 31, 2025
    What to do if Graco Water Pump operation is erratic?
    • V
      Veronica MejiaAug 31, 2025
      If your Graco Water Pump operation is erratic, it could be due to: * Exhausted fluid supply. Refill and reprime, or flush the pump. * Held open or worn intake valve or piston packings. Clear any obstructions and service the pump.
  • A
    alexmartinAug 25, 2025
    How to fix continuous air exhaust in my Graco Water Pump?
    • M
      melissabishopAug 25, 2025
      If your Graco Water Pump has continuous air exhaust, it is likely due to a worn or damaged air motor gasket, packing, seal, or similar components. The solution is to service the air motor.
  • H
    hailey17Sep 1, 2025
    What to do if Graco Water Pump operates, but output is low on downstroke?
    • A
      anthony23Sep 1, 2025
      If your Graco Water Pump operates, but the output is low on the downstroke, it could be due to a held open or worn intake valve. Clear any obstructions and service the pump.
  • J
    Jerome CoxSep 2, 2025
    What to do if my Graco 205626 operates, but output is low on both strokes?
    • B
      Bryan RamirezSep 2, 2025
      If your Graco Water Pump operates, but the output is low on both strokes, the issue might stem from inadequate air supply pressure or restricted air lines. To resolve this, increase the air supply and clear any obstructions. Another potential cause is closed or clogged valves, so ensure that the valves are open and clear.
  • D
    Deanna JonesSep 2, 2025
    Why is fluid coming out of the muffler of my Graco 205626?
    • J
      John MataSep 3, 2025
      If you notice fluid coming out of the muffler of your Graco Water Pump, it's likely due to a worn or damaged throat seal. The solution is to repair the seal.
  • M
    Marissa WhiteSep 3, 2025
    What to do if my Graco 205626 has erratic operation?
    • A
      April JacksonSep 3, 2025
      If your Graco Water Pump is experiencing erratic operation, it could be due to a couple of reasons. One possibility is an exhausted fluid supply; in this case, refill and re-prime or flush the pump. Another reason might be a held open or worn intake valve or piston packings, which would require clearing and servicing.
  • W
    Wayne CooperSep 4, 2025
    What to do if my Graco 205626 Water Pump operates, but output is low on down stroke?
    • D
      debraburnsSep 4, 2025
      If your Graco Water Pump operates, but the output is low on the down stroke, it may be due to a held open or worn intake valve. To address this, clear the valve and then service it.
  • M
    michaelkingSep 5, 2025
    What to do if my Graco 205626 Water Pump operates, but output is low on up stroke?
    • D
      David PhillipsSep 5, 2025
      If your Graco Water Pump operates, but the output is low on the up stroke, it could be due to held open or worn piston packings. The suggested solution is to clear the packings and then service them.
  • W
    Wanda MurraySep 5, 2025
    Why does my Graco Water Pump have continuous air exhaust?
    • T
      Tim WilliamsSep 5, 2025
      If your Graco Water Pump has continuous air exhaust, it is likely caused by a worn or damaged air motor gasket, packing, or seal. The suggested solution is to service the air motor.

Graco 205626 Specifications

General IconGeneral
Model Number205626
Power SourceAir
TypeDiaphragm Pump
Maximum Working Pressure100 psi (0.7 MPa, 7 bar)
Air Inlet Size1/4 in npt(f)
Fluid Inlet Size1/2" NPT
Fluid Outlet Size1/2" NPT
Wetted PartsPolypropylene, Santoprene
Maximum Pressure100 psi
Inlet Size1/2" NPT
Outlet Size1/2" NPT