EasyManua.ls Logo

Graco PRESIDENT 207-706 - User Manual

Graco PRESIDENT 207-706
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTRUCTIONS-PA
TS
LIST
ORAC0
SUPERSEDES
H
Rev.
J
This
manual
contains
IMPORTANT
WARNINQS
and
INSTRUCTIONS
READ AN0 RETAiN FOR REFERENCE
HYDRA-SPRAY"
36:I-RATIQ
PRESIDENT"
PU
36w
psi
(250
bad
MAXIMUM
WORKING
PRESSURE
Model
207-708
Series
E
55
Gallon
(200
liter) Size
Model
207-707
Series
D
10
Gallon
(38
liter) Size
10
Gellon
(38
liter) Size, with Severe-Duty Dispiace-
Model
217-518
Series
A
ment Pump'
'Severe-Duty Displacement Pumps have an abrasion
and corrosion resistant displacement rod and sleeve.
Refer to Technical Data on the back cover for
"wetted parts" information.
NOTE:
Conversion Kit
217-544
and Displacement
Pump
217-528
are available to convert
pumps
207-706
or
207-707
to severe-duty.
Refer to Accessories, page
14.
INDEX
Warnings
..........................................................
2
Operation
5
Installation
.4
Service
Troubleshooting Chart
......................................
6
Removing Air
Motor
or
Displacement Pump..
.........
7
Parts Drawing and List, Model
207-706
10
Displacement Pump Service
8
Accessories
13
Pem Drawing and List, Model
217-n8
12
Mounting
Hole
Layout
.......................................
-14
Dimensional Drawing
.........................................
14
Technical Data Back Page
How to Order Replacement Parts
14
Warranty
..............................................
Back Page
.......................................................
.........................................................
...............................
...................
Pam Drawing and List, Model
207-707
..................
.11
...................
.....................................................
..........................
.......................................
207.707
SHOWN
GRACO
INC. P.O.
BOX
1441
MINNEAPOLIS,
MN
55440-1441
Question and Answer IconNeed help?

Do you have a question about the Graco PRESIDENT 207-706 and is the answer not in the manual?

Overview

The Graco Hydra-Spray 30:1 Ratio President Pump is a high-performance, air-powered pump designed for industrial spraying applications, particularly those requiring high pressure. This device is capable of handling a maximum working pressure of 3600 psi (250 bar), making it suitable for a wide range of materials and demanding tasks. The pump is available in several models, including the 207-706 Series E for 55-gallon (200-liter) drums, the 207-707 Series D for 10-gallon (38-liter) drums, and the 217-578 Series A, also for 10-gallon (38-liter) drums, which features a Severe-Duty Displacement Pump.

The Severe-Duty Displacement Pumps (Model 217-578 Series A) are distinguished by their abrasion and corrosion-resistant displacement rod and sleeve, enhancing durability and extending the pump's lifespan when handling aggressive materials. Conversion kits (217-544) and displacement pumps (217-528) are available to upgrade standard 207-706 or 207-707 pumps to severe-duty configurations, offering flexibility and cost-effectiveness for users with evolving needs.

Technical Specifications:

  • Air Operating Range: 40-120 psi (3 to 8 bar)
  • Maximum Air Consumption: Approximately 35 scfm (0.98 m³/min) at 1 gpm (3.8 liter/min) at 100 psi (7 bar)
  • Maximum Recommended Pump Speed: 60 cycles/minute; 1 gpm (3.8 liter/min)
  • Recommended Speed for Optimum Pump Life: 15-25 cycles/minute; 0.15 to 0.25 gpm (0.6 to 0.9 liter/min)
  • Maximum Working Pressure: 3600 psi (250 bar)
  • Wetted Parts:
    • Models 207-706 & 207-707: Tungsten Carbide, Stainless Steel, Steel, Nitralloy/PTFE*, Leather
    • Model 217-578: Tungsten Carbide, Stainless Steel, Chrome over Stainless Steel/PTFE*, Leather, Ultra High Molecular Weight Polyethylene
  • Weight:
    • 207-706: 50 lb (23 kg)
    • 207-707: 24 lb (11 kg)
    • 217-578: 24 lb (11 kg)

Usage Features:

The pump is designed for ease of installation and operation. It requires a proper air supply and fluid lines, with clear instructions for connecting these components. The manual emphasizes safety, particularly regarding high-pressure fluid injection. Users are instructed to always follow the Pressure Relief Procedure before servicing, cleaning, or changing spray tips to prevent serious bodily injury. This procedure involves engaging the gun safety latch, turning off air to the pump, closing the bleed-type master air valve, disengaging the safety latch, relieving pressure into a grounded pail, and then opening the drain valve.

The pump's operation involves an air motor that drives a displacement pump, creating high-pressure fluid output. Troubleshooting guidance is provided for common issues such as low output on strokes, erratic operation, or pump failure, with solutions ranging from clearing restricted lines and refilling fluid supply to servicing internal components like packings and valve balls.

Maintenance Features:

Regular maintenance is crucial for the longevity and optimal performance of the Graco President Pump. The manual provides detailed instructions for servicing, including:

  • Removing Air Motor or Displacement Pump: This involves flushing the pump, disconnecting air and fluid lines, and unfastening the tie rod locknuts to separate the displacement pump from the air motor.
  • Displacement Pump Service: This section details how to disassemble and reassemble the intake valve and throat packings. It includes specific instructions for installing new packings, ensuring proper orientation (lips of v-packings facing down or up depending on the component), and lubricating them with Graco Pump Armor or compatible fluid. Different packing configurations are specified for various models (207-706/207-707 and 217-578), utilizing materials like PTFE, leather, and UHMWPE.
  • Repair Kits: Repair Kit 206-733 is available for displacement pump maintenance (models 207-706 and 207-707), and Repair Kit 220-397 for the 217-578 model. These kits contain necessary replacement parts like packings, o-rings, and seals.
  • Throat Seal Liquid: Graco Throat Seal Liquid (206-995/206-996) is recommended as a non-evaporating solvent for the wet cup, which helps maintain the throat packings.
  • Accessories: Various accessories are available to enhance pump functionality and maintenance, including air regulators, air line lubricators, surge tanks, air line filters, grounding clamps, suction hoses, filter/regulator/lubricator units, and pump runaway valve kits. These accessories help ensure clean air supply, proper lubrication, stable fluid flow, and safe operation.

The manual also includes parts drawings and lists for each model, facilitating the identification and ordering of replacement parts. Users are advised to provide the 6-digit part number, quantity, and part description when ordering from a Graco distributor. A mounting hole layout and dimensional drawing are provided for installation planning.

Safety:

Safety is paramount with this high-pressure equipment. The manual contains numerous warnings regarding fluid injection, splashing, and moving parts. It stresses the importance of proper grounding to prevent static electricity discharge, which could ignite flammable materials. Users are warned against operating the pump with air motor plates removed due to the risk of pinching or amputating fingers. Regular checks for leaks, abrasion, corrosion, and damaged components are essential to ensure safe operation. The warranty information outlines Graco's commitment to quality and specifies conditions under which the warranty applies.

Graco PRESIDENT 207-706 Specifications

General IconGeneral
BrandGraco
ModelPRESIDENT 207-706
CategoryWater Pump
LanguageEnglish

Related product manuals