Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
Copyright 2004, Graco Inc. is registered to I.S. EN ISO 9001
Installation and Operation
Fire-Ball
®
225, 300, and 425 Oil Pumps
For non-corrosive and non-abrasive oils
and lubricants only.
Mini Fire-Ball 225, 3:1
Parts 246775 and 248097
540 psi (3.7 MPa, 37 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Fire-Ball 300, 5:1
Parts 203876, 203872, 203857, 204254, and 222087
900 psi (6.2 MPa, 62 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Fire-Ball 425, 10:1
Parts 205626, 222065, and 222095
1800 psi (12.4 MPa, 124 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
309868 rev.B

Other manuals for Graco 205626

Questions and Answers

  • E
    Emily GonzalezSep 6, 2025
    Why Graco 205626 fails to operate?
    • R
      Randy RobertsSep 6, 2025
      Your Graco Water Pump might fail to operate due to several reasons. It could be due to inadequate air supply pressure or restricted air lines, in which case you should increase air supply and clear any obstructions. Other potential causes include closed or clogged valves (open and clean them), clogged fluid lines, hoses, valves, etc. (clear them). A damaged air motor (service the air motor) or an exhausted fluid supply (refill and reprime, or flush) could also be the reason.
  • I
    Isabella OnealSep 7, 2025
    What to do if Graco 205626 has continuous air exhaust?
    • K
      Kristin McdanielSep 7, 2025
      If your Graco Water Pump has continuous air exhaust, it is likely due to a worn or damaged air motor gasket, packing, or seal. To resolve this, service the air motor.

Graco 205626 Specifications

General IconGeneral
Model Number205626
Power SourceAir
TypeDiaphragm Pump
Maximum Working Pressure100 psi (0.7 MPa, 7 bar)
Air Inlet Size1/4 in npt(f)
Fluid Inlet Size1/2" NPT
Fluid Outlet Size1/2" NPT
Wetted PartsPolypropylene, Santoprene
Maximum Pressure100 psi
Inlet Size1/2" NPT
Outlet Size1/2" NPT

Related product manuals