Instructions – Parts List
GRACO INC.ąP.O. BOX 1441ąMINNEAPOLIS, MNą55440-1441
Copyright 1997, Graco Inc. is registered to I.S. EN ISO 9001
Huskyt 1040 Air–Operated
Diaphragm Pumps
120 psi (0.8 MPa, 8 bar) Maximum Fluid Working Pressure
120 psi (0.8 MPa, 8 bar) Maximum Air Input Pressure
Model No. 240623, Series C
With BSP manifolds and Tri-Clamp adapters
Model No. 240624, Series C
With bare BSP manifolds
Patent No.
CN ZL94102643.4
EU 0942171
US 5,368,452
AR AR006617B1
JA 3517270
308788 Rev.M
Important Safety Instructions
Read all warnings and instructions in this
manual and in instruction manual 308479
(supplied). Save these instructions.
7447C
Model No. 240623 shown

Questions and Answers

  • L
    Lance ArmstrongAug 20, 2025
    How to fix a Graco 240623 Water Pump that cycles at stall or fails to hold pressure?
    • C
      Christine NobleAug 20, 2025
      If your Graco Water Pump cycles at a stall or fails to hold pressure, it might be due to worn check valve balls, seats, or o-rings. If this is the case, you should replace them.
  • T
    Timothy DrakeAug 22, 2025
    Why is there fluid in the exhaust air of my Graco Water Pump?
    • J
      Jose KrauseAug 22, 2025
      Fluid in the exhaust air indicates that the diaphragm has ruptured, the diaphragm shaft bolt is loose, or the o-ring is damaged. In this case, you should replace the diaphragm, tighten the diaphragm shaft bolt, or replace the o-ring.
  • M
    Michelle ShannonAug 25, 2025
    What to do if my Graco 240623 Water Pump operates erratically?
    • A
      Angela BallardAug 25, 2025
      Erratic pump operation can be caused by a clogged suction line, sticky or leaking balls, a ruptured diaphragm, or a restricted exhaust. Inspect and clear the suction line, clean or replace the balls, replace the diaphragm, and remove any exhaust restrictions.
  • T
    Tonya NelsonAug 26, 2025
    Why does my Graco 240623 leak air externally?
    • E
      elizabeth34Aug 26, 2025
      External air leaks are often due to loose air valve cover screws or damaged air valve gaskets. Make sure that the air valve cover screws and air cover screws are tightened. Inspect the air valve gasket and air cover gasket for damage and replace if necessary.
  • C
    Craig BellAug 28, 2025
    What to do if Graco 240623 Water Pump will not cycle, or cycles once and stops?
    • S
      stevengonzalezAug 28, 2025
      If your pump isn't cycling, the air valve may be stuck or dirty, a check valve ball may be worn, or the dispensing valve could be clogged. Try disassembling and cleaning the air valve, replace the ball and seat, or relieve pressure and clear the dispensing valve. Also, consider installing a Pressure Relief Valve.
  • D
    Donald ThompsonAug 30, 2025
    Why are there air bubbles in the fluid from my Graco 240623?
    • C
      Chad JonesAug 30, 2025
      Air bubbles in the fluid can indicate a loose suction line, a ruptured diaphragm, loose inlet manifold, or damaged seals. Try tightening the suction line, replacing the diaphragm, tightening the manifold bolts, or replacing the seats or o-rings. Also, check and tighten or replace the diaphragm shaft bolt and replace any damaged o-rings.
  • S
    Sean WalkerAug 31, 2025
    Why does my Graco 240623 exhaust excessive air at stall?
    • B
      Bianca AndersonSep 1, 2025
      Excessive air exhaust at stall is often caused by worn components in the air valve. This includes the air valve block, o-ring, plate, pilot block, u-cups, or pilot pin o-rings. It can also be caused by worn shaft seals. Repair or replace the worn air valve parts or replace the worn shaft seals.
  • M
    Melissa HamiltonSep 2, 2025
    Why does my Graco 240623 Water Pump leak fluid externally from ball check valves?
    • H
      Henry MillerSep 3, 2025
      Fluid leaks from the ball check valves are often caused by loose manifolds or damaged seals. Ensure that manifold bolts are tightened, and replace any damaged seats or o-rings.
  • A
    Angel JohnsonSep 4, 2025
    What to do if my Graco 240623 will not cycle or cycles once and stops?
    • R
      Renee RobertsSep 4, 2025
      If your Graco Water Pump isn't cycling or stops after one cycle, several factors could be at play. Start by checking the air valve; it might be stuck or dirty, requiring disassembly and cleaning, and use filtered air. A severely worn check valve ball could be wedged in the seat or manifold, necessitating replacement of both the ball and seat. Over-pressurization can also cause the check valve ball to wedge into the seat, in this case install a Pressure Relief Valve. Lastly, a clogged dispensing valve can halt the cycling process; relieve the pressure and clear the valve.
  • M
    Michelle AndersonSep 6, 2025
    What causes fluid in the exhaust air of a Graco Water Pump?
    • S
      shessSep 6, 2025
      If you find fluid in the exhaust air of your Graco Water Pump, it's likely due to a ruptured diaphragm, which will need replacement. Another potential cause is a loose fluid side plate, which should be tightened or replaced.

Graco 240623 Specifications

General IconGeneral
BrandGraco
Model240623
CategoryWater Pump
LanguageEnglish