EasyManua.ls Logo

Graco 240623 - User Manual

Graco 240623
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Instructions – Parts List
GRACO INC.ąP.O. BOX 1441ąMINNEAPOLIS, MNą55440-1441
Copyright 1997, Graco Inc. is registered to I.S. EN ISO 9001
Huskyt 1040 Air–Operated
Diaphragm Pumps
120 psi (0.8 MPa, 8 bar) Maximum Fluid Working Pressure
120 psi (0.8 MPa, 8 bar) Maximum Air Input Pressure
Model No. 240623, Series C
With BSP manifolds and Tri-Clamp adapters
Model No. 240624, Series C
With bare BSP manifolds
Patent No.
CN ZL94102643.4
EU 0942171
US 5,368,452
AR AR006617B1
JA 3517270
308788 Rev.M
Important Safety Instructions
Read all warnings and instructions in this
manual and in instruction manual 308479
(supplied). Save these instructions.
7447C
Model No. 240623 shown

Questions and Answers

  • J
    jessica27Sep 8, 2025
    Why does my Graco Water Pump operate erratically?
    • C
      Casey JacksonSep 8, 2025
      If your Graco Water Pump is operating erratically, consider these potential causes: a clogged suction line, which needs inspection and clearing; sticky or leaking balls, which should be cleaned or replaced; a ruptured diaphragm, which requires replacement; or a restricted exhaust, which needs the restriction removed.
  • J
    James KirkSep 10, 2025
    Why is my Graco Water Pump leaking air externally?
    • Y
      Yolanda BurkeSep 10, 2025
      If your Graco Water Pump is leaking air externally, it could be due to a few reasons. The air valve cover or its screws might be loose, so tighten them. Alternatively, the air valve gasket or air cover gasket could be damaged, requiring inspection and replacement. Also check if the air cover screws are loose and tighten them if necessary.
  • P
    Paul RaySep 12, 2025
    Why is my Graco 240623 leaking fluid externally from the ball check valves?
    • S
      Stephanie RodriguezSep 12, 2025
      If your Graco Water Pump is leaking fluid externally from the ball check valves, it could be due to loose manifolds, a damaged seal between the manifold and seat, or damaged o-rings. To resolve this, tighten the manifold bolts or replace the seats or o-rings.
  • G
    Gregory MartinezSep 14, 2025
    What causes air bubbles in the fluid of a Graco 240623?
    • C
      Craig SmithSep 14, 2025
      Air bubbles in the fluid of your Graco Water Pump can stem from several issues: * A loose suction line. * A ruptured diaphragm. * Loose inlet manifold, damaged seal between manifold and seat, or damaged o-rings. * Loose fluid side plate. * Damaged o-ring. To resolve this, tighten the suction line, replace the diaphragm, tighten the manifold bolts or replace the seats or o-rings, tighten or replace the fluid side plate, or replace the o-ring.
  • J
    Joshua JonesSep 15, 2025
    Why does my Graco 240623 cycle at stall or fail to hold pressure?
    • E
      Emily GregorySep 16, 2025
      If your Graco Water Pump cycles at stall or fails to hold pressure, it may be due to worn check valve balls, seats, or o-rings. In this case, replace the worn parts.
  • T
    Terrance MccallSep 18, 2025
    Why is my Graco Water Pump leaking fluid externally from ball check valves?
    • M
      meaganmaloneSep 18, 2025
      If your Graco Water Pump is leaking fluid externally from the ball check valves, it could be due to loose manifolds, a damaged seal between the manifold and seat, or damaged o-rings. To fix this, tighten the manifold bolts or replace the seats or o-rings.