Pressure Relief Procedure
8 309574C
Pressure Relief
Procedure
1. Relieve pressure in gun and perform gun shutdown
procedure. See gun manual.
2. Verify gun fluid manifold valves A and B are closed.
3. Shut off feed pumps and agitator, if used.
TI2421A
4. Turn PRESSURE RELIEF/SPRAY valves (SA, SB)
to PRESSURE RELIEF. Route fluid to waste con-
tainers or supply tanks. Ensure gauges drop to 0.
5. Engage gun piston safety lock.
6. Disconnect gun air line and remove gun fluid mani-
fold.
TI2481A
SA
SB
TI2409A