Setup
14 332689D
Setup
Prime and Flush Storage Fluid.
Before you use your sprayer for the first time or begin a
new spraying project, you need to prime the sprayer and
flush the storage fluid out of the sprayer.
• When spraying water-based materials, flush the
system thoroughly with water. The water flowing out
of prime tube should be clear and solvent-free
before you begin spraying the water-based mate-
rial.
• To avoid fluid splashing back on your skin or into
your eyes, always aim gun at inside wall of pail.
1. Unscrew tip and guard assembly from gun.
2. Uncoil hose and connect one end to gun. Use two
wrenches to tighten securely.
3. Connect other end of hose to sprayer.
NOTE: If hose is already connected, make sure connec-
tions are tight.
4. Turn Pressure Control Knob all the way left
(counter-clockwise) to minimum pressure.
5. Make sure the power switch is OFF and the sprayer
is unplugged.
6. Separate prime tube (smaller) from suction tube
(larger).
7. Place prime tube in waste pail.
8. Submerge suction tube in water