EasyManua.ls Logo

Graco Ultra Max II 650 PC Pro - Sprayer Startup; Building Pressure and Leak Inspection

Graco Ultra Max II 650 PC Pro
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Startup
16 3A6491E
Startup
1. Perform Pressure Relief Procedure,
page 12.
2. Turn pressure control to lowest
pressure.
3. Turn ON/OFF switch to ON position.
4. Place fluid intake in paint pail. Place
drain tube in waste pail.
5. Turn pressure control to Fast Flush to
start motor. Allow paint to circulate
through drain tube for 15 seconds.
6. Turn prime valve horizontal. Disengage
trigger lock.
7. Hold gun against grounded metal waste
pail. Trigger gun until paint appears.

Related product manuals