Document No. Graf-0004 Rev. 1
ONECLEAN TANKS
LOG BOOK
The drainage system from this property discharges to a
wastewater treatment plant (or septic tank, as appropriate). The
owner is legally responsible for routine maintenance and to ensure
that the system complies with any discharge consent issued by
the relevant authority for your area and that it does not present a
health and safety hazard or a nuisance.
Graf UK recommend service and maintenance should be carried out
at least once a year by a qualied engineer.
For further details contact Graf UK on 01608 661500.

Other manuals for Graf one2clean

Questions and Answers

  • L
    Lynn DaughertySep 8, 2025
    What to do if the compressor current is too low in my Graf Tank Equipment?
    • O
      owhiteSep 8, 2025
      If the compressor current on your Graf Tank Equipment is too low, it could mean the compressor isn't working or isn't receiving power. To address this, check the compressor in manual mode.
  • J
    Jenna WeaverSep 10, 2025
    How to troubleshoot no display and no light on Graf Tank Equipment?
    • M
      Maria McbrideSep 10, 2025
      If your Graf Tank Equipment shows no display and no light, it could be due to a power failure, the system being turned off, or no voltage at the control cabinet. Check the power supply to the system and control system. Turn the system back on. Check the supply to the control cabinet. Wait for resumption of power supply.
  • P
    Phyllis ClarkSep 12, 2025
    Why is there compressor overcurrent in my Graf Tank Equipment?
    • R
      Richard RuizSep 12, 2025
      If you're experiencing compressor overcurrent on your Graf Tank Equipment, it might be due to a short-circuit. Check the supply to the control cabinet.
  • E
    Elizabeth HurstSep 13, 2025
    What causes one-sided ventilation or large air bubbles in Graf Tank Equipment?
    • T
      Thomas EvansSep 13, 2025
      If the ventilation in your Graf Tank Equipment is one-sided or large air bubbles appear, it could be due to a defective membrane unit or leaky air admittance valves. Contact a maintenance company to address this issue and to seal leaky air admittance valves.
  • J
    Jared TorresSep 15, 2025
    How to set the clock on Graf Tank Equipment?
    • C
      Crystal McmillanSep 15, 2025
      To set the clock on your Graf Tank Equipment, navigate to the menu item and set the date and time, because the internal clock/date may not be set.
  • A
    aaroncastroSep 18, 2025
    What to do if my Graf Tank Equipment has no display, but the light is green?
    • M
      Melissa FullerSep 18, 2025
      If your Graf Tank Equipment shows no display but the light is green, turn the system off and then back on again after waiting for 10 seconds.

Summary

One2 Clean System Benefits

Bin It Dont Flush It Guidelines

General Notes

Function of the Wastewater Treatment System

Step 1: Aeration

Wastewater is subjected to aerobic treatment for a fixed amount of time, with microorganisms supplied oxygen.

Step 2: Settling

No aeration; activated sludge settles, forming clear water zone and mud layer.

Step 3: Clear Water Removal

Biologically treated wastewater is extracted using a mammoth pump principle (air lift pump).

Start-up of the Control System

Operation of the Control System

Control Programme

System switches outputs for air compressors and motors on timer based on sequence tables.

Operating the Control System

How to query system parameters and navigate through different operating levels.

Manual Control of the Valve

How to operate individual valves manually for testing and checks.

Set Date;Time

Procedure for setting the system's current date and time for accurate logging.

Setting-up Holiday Mode

How to configure reduced system operation for periods of non-use.

Old Faults

Accessing and viewing historical fault messages with date and time.

Display Settings

Viewing current control system settings without making changes.

Service Menu

Accessing advanced settings for qualified personnel, protected by a code.

Inspection and Maintenance

Obligations of the Operator

Operator's duty for fault-free operation, daily and monthly checks.

Maintenance by a Specialist Company

Tasks and frequency for professional maintenance, including contract requirements.

Determination of Sludge Removal

How to measure SV30 to determine the need for sludge removal.

Sludge Removal

Step-by-step guide for removing sludge from the wastewater treatment tank.

Fault Messages and Troubleshooting

System Behaviour after switching off the Power Supply

How the system behaves during and after a power outage.

Fault Message in the Display

Explains fault codes, display messages, and indicator lights.

Unusual Water Levels - Fixing a Fault

Troubleshooting guide for issues related to water levels and system smells.

Operating Notes

EC Declaration of Conformity

Declaration of Performance

Technical Data of the Control System

Warranty Information

Warranty Clause

Details the 10-year warranty for underground tanks, excluding parts and accessories.

Warranty Conditions

Conditions for warranty, including installation, commissioning, and maintenance by specialists.

Graf one2clean Specifications