EasyManuals Logo

Gram KF 310 User Manual

Gram KF 310
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
9
There has been a power failure, the power
supply to the refrigerator has been
disconnected or the temperature in the
refrigerator has been higher than the set
temperature for more than two hours.
Interrupting an alarm
The acoustic alarm can always be
interrupted by opening the door and
pressing any button.
An alarm code will be displayed even
though the reason for the alarm no
longer exists. To remove the alarm
code, press buttons (7) and
(8) simultaneously for 2-3 seconds. An
acoustic alarm cannot then be given
for the next two hours.
GB
Alarm
Normal use of the refrigerator/freezer
may give rise to various disruptions with
unstable cabinet function as a
consequence. These disruptions are
shown on the display by means of an
alarm code (an E followed by a number)
and an acoustic signal is given.
In case of several faults, the alarm
codes will be displayed in turn.
Alarm codes
E1 - Temperature sensor fault in
refrigerating compartment
E2 - Temperature sensor fault in
freezing compartment
E3 - Evaporator sensor fault
E4 - Open door
E5 - Temperature too high
E6 - Temperature too high at power
failure
E1, E2 and E3
One of the temperature sensors has
been damaged. Call service. A built-in
emergency program maintains an
acceptable temperature until the fault
is corrected.
E4
The door to the refrigerating or freezing
compartment is open for more than two
minutes. The alarm code disappears
when the door is closed. If the door is
opened and closed repeatedly within a
short space of time, the interior light will
eventually switch off.
E5
The temperature in the refrigerating or
freezing compartment has been higher
than the set temperature for more than
two hours.
E6
99
99
9
88
88
8
and may occur when for example fresh
items of food are stored in the refrigerator/
freezer or when the door is open for longer
periods. Items of food in the cabinet will
not be affected by these variations and the
temperature will quickly return to normal.
The interior light is turned on when the
door to the refrigerating compartment is
opened. When the door is closed again,
the light remains switched on for about 5
seconds. If the door is still open about two
minutes later, the interior light is turned off.
Alarm E4 is displayed, and an acoustic
signal is given. If the door to the freezing
compartment is also open for more than
two minutes, Alarm E4 is activated, and an
acoustic signal is given.