26
Gram
Commercial
Technical information
765041466
Description :
Operation- and servicemanual
Gram Process KPS
Compiled. Latest revision. Deleted.
Date Name Date Name Rev.no Date Name
30.09.11 JP 000
Paramete
r
Description Default Min. Max.
B09 Surface temperature min. value allowed during phase 3 0
-50C 99C
B10 End of IFR cycle core temperature
4C -50C 99C
B11 Delay from the positive result of the probe test, for
starting the procedure to determine the end of phase 1
60 sec 0 sec 99 sec
B12 Phase 1 temperature detection time 30 sec 0 sec 99 sec
B13 Phase 1 min. duration 6 min 0 min 99 min
B16 Defrost on starting IFR cycle
(0=no; 1=yes)
0 0 1
B17 Inhibition temperature
90C -50C 99C
B18 Room setpoint in the event of automatic switch to time or
temperature mode
-7C -50C 99C
B19 Max. duration possible for IFR process 999 min 1 min 999 min
B20 Surface temperature safety value determining the end of
phase 1
-1C -50C 99C
B21 First coefficient of the room sensor curve (phase 3) 10 -90 99
B22 Second coefficient of the room sensor curve (phase 3) -50 -90 99
B23 Storing activation at the end of IFR cycle
(0=no; 1=yes)
1 0 1
B24 Room sensor setpoint in storing
2C -90C 90C
B26 Core temperature limit for the timer start 999 0 999
B27 Adjuster of fan speed in the phase 3 99 0 99
B28 Cold pulse adjuster 10 0 99
Communication
ADD Device address 1 1 147
SC Serial control
0=not activated
1=print
2=ModBus (RS485)
1 0 2
MB1 Baud rate: 0=2400; 1=4800; 2=9600; 3=18200 2 0 3
MB2 Parity: 0=no parity; 1=odd; 2=even 2 0 2
Type of cycle
G01 Positive QC cycles only:
0=positive and negative
1=positive only
0 0 1