Grant Vortex Indoor/Utility, System and Boiler House Oil Boilers
4 - GENERAL BOILER INFORMATION
Boiler description
4.1
White system ...... High level and vertical concentric
balanced flue kit - components available:
Extensions 225 mm, 450 mm, 950 mm, adjustable
275 to 450 mm and 45° elbow
Vertical concentric balanced flue kit
Extensions 225 mm, 450 mm, 950 mm, adjustable
275 to 450 mm and 45° elbow
All burners are pre-set for use with kerosene and are
supplied ready to connect to a single pipe fuel supply
system with a loose flexible fuel line and
3
/
8
" to
1
/
4
" BSP
male adaptor supplied with the boiler.
If required, an additional flexible fuel line (600 mm) and
3
/
8
" to
1
/
4
" BSP male adaptor are available to purchase
from your local stockist, for two-pipe oil supply systems.
The temperature of the water leaving the boiler to heat
the radiators and hot water cylinder is User adjustable.
The boiler is fitted with an overheat thermostat (which
allows it to be used on a sealed central heating system) which
will automatically switch off the boiler if the heat exchanger
exceeds a pre-set temperature of 111° C ± 3° C.
The control panel is fitted with an ON/OFF switch,
boiler thermostat control knob and the manual reset
button for the overheat thermostat.
Boiler components
4.2
The Grant Vortex range of automatic pressure jet oil
boilers have been designed for use with a fully pumped
central heating system with indirect domestic hot water
cylinder. They are not suitable for use with either a direct
cylinder or a 'primatic' cylinder or gravity hot water..
The boilers are suitable for use on open vented or
sealed central heating systems. System models are
supplied with the necessary components factory fitted.
See Section 4.13.
All models are supplied with the control panel and
burner factory fitted.
The boilers can be connected to either a conventional
flue system or a balanced flue system, as required.
For Conventional flue applications where a chimney is
to be lined - Grant recommends the use of the Grant
‘Orange’ flue system, specifically designed for the
Vortex range of condensing boilers. Refer to Section
4.7 for further details.
Important: The flue system materials and construction
MUST be suitable for use with oil-fired condensing
boilers. Failure to fit a suitable conventional flue may
invalidate the warranty on the boiler.
Fitting instructions for the Low level concentric, High level
and Vertical balanced flue kits are supplied with the kits.
Where a balanced flue system is required, the following
flue kits are available from your local stockist.
Refer to Section 4.8 for further details.
Yellow system..... Standard low level concentric
balanced flue - components available:
Low level concentric balanced flue short
Extensions 225 mm, 450 mm and 675 mm
90° extension elbow
45° extension elbow
45° elbow
Where it is not possible to terminate the low level flue
at low level, a plume diverter kit is available for fitting
to the low level flue. The plume diverter kit diverts the
flue gases up and terminates at a higher level. When
fitting the plume diverter kit, follow the instructions
supplied with the kit. See Fig. 10b.