JB Academy, JB Nova and SUB Aqua Pro 31394 V7
Detailed operating manual Page 1
www.grantinstruments.com
Unstirred Water Baths
JB Academy
JB Nova
SUB Aqua Pro
Operating Manual
www.grantinstruments.com
salesdesk@grantinstruments.com
Tel: +44 (0)1763 260811

Table of Contents

Other manuals for Grant JBN5

Questions and Answers

  • T
    Taylor JacobsAug 10, 2025
    Why temperature continues to rise when not expected in Grant Laboratory Equipment?
    • T
      Timothy NicholsonAug 10, 2025
      If the temperature continues to rise unexpectedly in your Grant Laboratory Equipment, it may be because the set temperature is higher than the liquid temperature. Ensure the bath set temperature is correct. Alternatively, the set temperature might be too close to the ambient temperature. In this case, increase the set temperature, keeping in mind that the minimum temperature should be 5°C above ambient.
  • M
    Miss Wendy DavisAug 16, 2025
    How to resolve if temperature does not rise when expected in Grant Laboratory Equipment?
    • C
      Crystal LewisAug 16, 2025
      If the temperature in your Grant Laboratory Equipment isn't rising as expected, the set temperature might be lower than the liquid temperature. Verify that the bath set temperature is correct. Also, if the set temperature is too close to ambient, increase it, noting that the minimum temperature should be 5°C above ambient.
  • K
    kylefriedmanAug 25, 2025
    What to do if Grant Laboratory Equipment display shows '????'?
    • P
      Patrick CastroAug 25, 2025
      If the Grant Laboratory Equipment display shows '????', it could indicate a faulty temperature probe. A competent person should check the probe for an open or short circuit fault, or contact Grant.
  • M
    Mitchell SimonSep 2, 2025
    What to do if the Grant Laboratory Equipment display shows '???'?
    • T
      tomhollandSep 2, 2025
      If the Grant Laboratory Equipment display shows '???', it means that the bath is running on its default settings. Contact Grant Instruments' Service Department for assistance.

Summary

Safety Information

Safety Symbols

Explains various safety symbols used on equipment and in the manual.

Safety Warnings

Provides critical safety warnings related to operation, fluids, and environment.

Operating Instructions

Operating Procedures

Operation

General operational guidelines for the water bath.

Operating the Bath Without Water

Explains dry start protection and its implications.

Using the Water Bath

Setting the Control Temperature

Step-by-step guide to setting the bath's temperature.

Setting the Control Temperature and Keypad Lock

Guide to setting temperature and keypad lock on JB Nova.

Bath Controls

Identifies controls on the SUB Aqua Pro bath.

Setting the Control Temperature

Guide to setting temperature on the SUB Aqua Pro.

Setting the Over Temperature Protection

How to set the over-temperature protection limit.

Calibration

Single Point Calibration

Detailed guide for single point calibration procedures.

Dual Point Calibration

Detailed guide for dual point calibration procedures.

Technical Specifications

Maintenance and Service

Service

Troubleshooting

Grant JBN5 Specifications

General IconGeneral
BrandGrant
ModelJBN5
CategoryLaboratory Equipment
LanguageEnglish