JB Academy, JB Nova and SUB Aqua Pro 31394 V7
Detailed operating manual Page 1
www.grantinstruments.com
Unstirred Water Baths
JB Academy
JB Nova
SUB Aqua Pro
Operating Manual
www.grantinstruments.com
salesdesk@grantinstruments.com
Tel: +44 (0)1763 260811

Table of Contents

Other manuals for Grant SAP2

Questions and Answers

  • T
    theresa61Aug 10, 2025
    Why temperature continues to rise when not expected in Grant Laboratory Equipment?
    • R
      Richard CruzAug 10, 2025
      If the temperature continues to rise unexpectedly in your Grant Laboratory Equipment, it may be because the set temperature is higher than the liquid temperature. Ensure the bath set temperature is correct. Alternatively, the set temperature might be too close to the ambient temperature. In this case, increase the set temperature, keeping in mind that the minimum temperature should be 5°C above ambient.
  • B
    barbershannonAug 17, 2025
    How to resolve if temperature does not rise when expected in Grant Laboratory Equipment?
    • J
      jeremiahhawkinsAug 17, 2025
      If the temperature in your Grant Laboratory Equipment isn't rising as expected, the set temperature might be lower than the liquid temperature. Verify that the bath set temperature is correct. Also, if the set temperature is too close to ambient, increase it, noting that the minimum temperature should be 5°C above ambient.
  • W
    William BrownAug 26, 2025
    What to do if Grant Laboratory Equipment display shows '????'?
    • J
      Jonathan GarciaAug 26, 2025
      If the Grant Laboratory Equipment display shows '????', it could indicate a faulty temperature probe. A competent person should check the probe for an open or short circuit fault, or contact Grant.
  • C
    Carla VillarrealSep 1, 2025
    What to do if the Grant Laboratory Equipment display shows '???'?
    • N
      Nicole SimsSep 1, 2025
      If the Grant Laboratory Equipment display shows '???', it means that the bath is running on its default settings. Contact Grant Instruments' Service Department for assistance.

Summary

Safety Information

Safety Compliance

Specifies compliance with international safety standards like IEC 61010.

Safety Symbols

Explanation of safety symbols used on the equipment and in the manual.

Safety Warnings

Provides critical warnings regarding safe operation and potential hazards.

Operating Instructions

Electrical Supply

Checks for correct voltage and ground connection for the mains supply.

Operating Procedures

Operating Without Water (Dry Start)

Explains dry start protection and its implications.

Allowing Bath to Run Dry (DPA)

Details the Dry Protection Alarm (DPA) feature and its management.

Using with Heat Transfer Beads (HES)

Instructions for operating the bath with heat transfer beads.

Using the Water Bath

Setting Over Temperature Protection

Guides setting the maximum temperature limit to protect samples.

Calibration

Technical Specifications

Maintenance and Service

Service

Procedure for contacting Grant Instruments for service or repairs.

Troubleshooting

Grant SAP2 Specifications

General IconGeneral
BrandGrant
ModelSAP2
CategoryLaboratory Equipment
LanguageEnglish