17. Specifi cation
Battery:
Charge currents / power 100 mA to 8 A / max. 50 W with internal power supply 100~240 V AC
100 mA to 8 A / max. 700 W
with external 11...15 V DC power
10 battery memories
Ni-Cd & Ni-MH batteries:
Cell count 4 - 10 cells
automatic detection NiCd/NiMH
peak 3 ~ 20 mV/cell
Lithium batteries:
Cell count 1-4 cells
Cell voltage 3,3V (LiFe), 3,6 V (LiIo), 3,7 V (LiPo)
USB - socket: 5 V DC, 500 mA
General:
Operating voltage range DC input: 11.0 to 15 V
Operating voltage range AC input: 100 ~ 240 V
Car battery required 12 V, min. 60 Ah
Mains PSU required: 12 - 14V, min. 12 A stabilised
1)
Idle current: approx. 100 mA
Low-voltage cut-off approx . 10.5 V
Balancer connector: 1...4 LiPo/LiIo/LiFe cells
Balancing current: 0.3 A LiPo/LiIo/LiFe
Safety timer: off, 300 min.
Trickle charge: 0 ~ 250 mA (automatic 1/20 of the preset charge current)
Weight approx. 570 g
Dimensions approx. (WxDxH) 165 x 140 x 58 mm
Firmware-Update via Mini USB socket
All data assumes a car battery voltage of 12.5 V.
The stated values are approximate only; they may vary depending on the state of the battery being charged, temperature etc.
1)
When powered by a mains PSU, the charger will only operate correctly if the PSU is suitable in terms of voltage, stability, maximum load capacity etc. You can avoid problems by using only the PSUs
which we specifi cally recommend.