CCT10/CCT20 USER MANUAL
7
KEY DESCRIPTION for MODEL CCT10
Press and hold this key for 2 seconds to turn off the scale.
Press this key briefly to turn on the scale. A self-test will run on the display
and then stabilize showing zero
Select the desired weight unit in setup mode.
Reset the weight to zero “0”, but the display value has to be lesser than
±
2% of maximum capacity. In the setup mode, it means moving up.
Tare: Subtract the container´s weight. Maximum tare = full capacity
Preset Tare: Press Tare key with no object on the pan. Use 0 ~ 9 number
keys to enter the preset tare weight value. Press the tare key to confirm.
Clear Preset Tare: Press the Tare key again to clear the preset tare with no
object on the pan.
In the setup mode, it means moving up.
Manually set up piece weight. Use 0~9 number key and decimal【.】key to
enter piece weight,and then press【count】key to initiate counting.
Weight window displays total weight,piece weight window displays piece
weight,and total count window displays the counts.
When weight window displays weight, use 【0~9】number keys to set
sample size and press【sample】key to initiate the calculation of piece
weight.
Set count alarm: Press this key when total count window displays pieces
to set the alarm. The current count is set as the alarm count. When the
counting number is greater than this set number, PIECE WEIGHT window
shows -q hi -- -- and the buzzer starts to alarm.
Clear count alarm:press and hold the【Count Alarm】key until buzzer
beeps twice。Set point will auto cancel when turn off the scale.