Instruction manual - VARIABLE SPEEDSWIMMING POOL PUMP14
6. MAINTENANCE / STORAGE & WINTERIZATION:
Maintenance
Clean strainer basket regularly. Do NOT strike basket to clean. Inspect strainer cover gasket regularly and re
-
place as necessary.
• Pumps have self-lubricating motor bearings and shaft seals. No lubrication is necessary.
• Keep motor clean. Do NOT use water to hose off motor.
• Occasionally, shaft seals must be replaced, due to wear or damage. Replace with genuine seal assembly kit.
Storage & Winterization
WARNING – Separation or Explosion Hazard.
• Do not purge the system with compressed air. Purging the system with compressed air can cause components
to explode, with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), high
volume blower when air purging the pump, filter, or piping.
ATTENTION
– Allowing the pump to freeze will void the warranty.
Use ONLY propylene glycol as antifreeze in your pool/spa system. Propylene glycol is nontoxic and will not
damage plastic system components; other anti-freezes are highly toxic and may damage plastic components in
the system.
• Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long
time (see instructions below).
Keep pump dry and covered during storage. To avoid condensation/corrosion problems, do NOT cover or wrap
pump with plastic film or bags.
STORING PUMP FOR WINTERIZATION
WARNING To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before draining
pump. Failure to disconnect power may result in serious personal injury or death.
• Drain water level below all inlets to the pool.
• Remove drain plugs from bottom of strainer body, and remove strainer cover from strainer housing.
• Disconnect pump from mounting pad, wiring system and plumbing system.
• Once the pump is empty of water, re-install the strainer cover and drain plugs. Store pump in a dry area.
7. TECHNICAL DATA:
Code Input Power Voltage Hertz Frequency Max Head Max Flow Rate Wire Size
VSG75 750 W 230V 50Hz 50Hz 14 m.c.w. 20 m3/h H07RN-F