32
Operation procedures/pictures
8.2.8 Disassembling the big valve and small valve
● Screw off the 2 pieces of bolts that fix the big valve
and unsolder the solder joint between the big valve
and air return pipe to take off the big valve.(As
shown in Fig.8-25)
(Note: When unsoldering solder joint, wrap the big valve
completely with wet cloth to avoid high-temperature damage
to the valve body.)
● Screw off the 2 pieces of bolts that fix the small
valve and unsolder the solder joint between the
capillary assy and the small valve to take off the
small valve.(As shown in Fig.8-25)
Fig.8-25
8.2.9 Disassembling the capillary assy
● Unsolder the 2 solder joints between the capillary
assy and the small valve and between the capillary
and the condenser to take off the capillary assy.(As
shown in Fig.8-26)
Capillary assy
Fig.8-26
Bolts
Small valve
Bolt (2 pieces)
Big valve