3 INSTALL THE UNIT
3�1 Install the rear panel
(1) Always mount the rear panel horizontally. 
Due  to  the  water  tray  of  indoor  unit  has  been 
adopted the both-way drainage design, the outlet 
of  water  tray  should  be  adjusted  slightly  down 
when installing, that is taking the outlet of the water 
tray as  the  center  of  a circle,  the  included  angle 
between the evaporator and level should be 0  or 
more, that is good for condensing water drainage.
(2) Fix the rear panel on the wall with screws. 
(Where is pre-covered with plastic granula )
(3) Be sure that  the rear panel  has been xed  rmly enough to  withstand the weight of an adult of 60kg, 
further more, the weight should be evenly shared by each screw.
3�2 Install the piping hole
① 
Ake the piping  hole  (Ф55)  in the wall at a slight  downward  slant  to the 
outdoor side. 
② 
Insert the piping-hole sleeve into the hole to prevent the connection piping 
and wiring from being damaged when passing through the hole.
3�3 Install the water drainage pipe
(1) For well draining, the drain hose should be placed at a downward slant.
(2) Do not wrench or bend the drain hose or ood its end by water.(As 
show in Fig.6)
(3) When the long drainage hose passing through indoor, should wrap 
the insulation materials.                                                                                                    
Note:
When connecting the  electric  wire  if the wire length is  not  enough, 
please  contact  with  the  authorized  service  shop  to  buy  a  exclusive 
electric wire that is long enough and the joint on the wire are not allowed.
● The electric wiring must be correctly connected, wrong connection 
may cause spare parts malfunction.
● Tighten the terminal screw in order to prevent loose.
● After tighten the screw, slight pull the wire and conrm 
whether is it rm or not.
● If the earth wire is wrong connection, that may  cause 
electric shock.
●  The  cover  plate  must  be  fixed,  and  tighten  the 
connection wire, if it is poor installed, that the dust, moisture 
may enter  in or the  connection terminal will  be affected by 
outside force, and will cause re or electric shock.
3�4 Install the unit
● The piping can be lead out from right, right rear, left ,left 
rear.
(1) When  routing  the  piping  and  wiring  from the left or 
right side of indoor unit, cut off the tailings from the chassis 
in necessary(Show in Fig.7)
1)  Cut off the tailings 1 when routing the wiring only; 
2)  Cut off the tailings 1 and tailings 2 when routing both 
the wiring and piping.
(2) Take out the  piping from body case, wrap the piping 
electric wire, water pipe with tape and pull them through the 
piping hole (As show in Fig.8)
(3) Hang the mounting slots of the unit on the upper tabs 
of the rear panel and check if it is rm enough.(As show in 
Fig.9)
(4) The height of the installed location should be 2.5 m or more from the oor.
mm051
mm55
mm55
mm051
Wall
Wall
Mark on the middle of it 
Gradienter
Left
Right
(Rear piping hole) 
(Rear piping hole) 
Space
to the
wall
above
Space
to the
wall
above
Fig. 5