EasyManua.ls Logo

Gree GDN12AJ-K4EBC1A - 8 Maintenance; Error Code

Gree GDN12AJ-K4EBC1A
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Maintenance
Service Manual
8.Maintenance
8.1 Error Code
No.
Malfunction
Name
Nixie tube display Unit status Possible Causes
1
Malfunction of
ambient temp.
sensor
F1
The compressor, fan
and water pump stop;
buttons are invalid
1. The wiring terminal between ambient temperature
sensor and main board is loosened or poorly
contacted;
2. There’s short circuit due to trip-over of the parts on
controller;
3. Ambient temperature sensor is damaged (Please
check it by referring to the resistance table for
temperature sensor);
4. Main board is broken.
2
Malfunction
of tube temp.
sensor
F2
1. The wiring terminal between evaporator temperature
sensor and main board is loosened or poorly
contacted;
2. There’s short circuit due to the trip-over of the parts
on controller;
3. Evaporator temperature sensor is damaged
(Please check it by referring to the resistance table for
temperature sensor);
4. Main board is broken.

Other manuals for Gree GDN12AJ-K4EBC1A

Related product manuals