Loading...
Error Codes
Unit's Malfunction Codes
No.
Malfunction
Name
Display
Code
Unit's
Condition
Possible Causes
Display
Window
1
Ambient
Temperature
Sensor
Malfunction
F1
Compressor
and fan
motor stop.
Buttons are
invalid.
Ambient temperature sensor is
loosen or is poorly connected
with the terminal of display board.
Some element of display board
may have been put upside down
and cause short circuit.
Ambient temperature sensor is
damaged
.
Display board is damaged.
2
Tube
Temperature
Sensor
Malfunction
F2
Temperature sensor on the
evaporator is loosen or is poorly
connected with the terminal of
display board.
Some element of display board
may have been put upside down
and cause short circuit.
Temperature sensor on the eva-
porator is damaged.
Display board is damaged.
3
Humidity
Sensor
Malfunction
L1
Humidity sensor is short-circuited.
Humidity sensor is damaged.
Display board is damaged.