pressure).
(4) Install the new solenoid valve coil to the exact position.
(5) Use a torque wrench to fix the solenoid valve coil.
(6) Fix the wires according to the original requirements by referring to the unit wiring diagram.
(7) Make sure that the components and cables are properly connected.
(8) Install the panel.
5.14 Removing and Installing Blades
Preparations
(1) Use the power circuit breaker to switch off the power of the GMV6 VRF system.
(2) Remove the unit top cover assembly.
Removing procedure
(1) Use a wrench to remove the fastening nut, spring washer, and flat piece in sequence.
(2) Take off the blade
.
Installation procedure
(1) Use the power circuit breaker to switch off the power of the GMV6 VRF system; install the blades
on the motor shaft and check if they are fixed properly.
(2) Use a wrench to install the fastening nut, spring washer, and flat piece in sequence.
(3) Rotate the blade
and check the gap between the blade and baffle ring.
(4) Install the top cover assembly and panel assembly.
1 - nut; 2 - spring washer; 3 - flat piece; - blade.

Other manuals for Gree GMV-280WM/G-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GMV-280WM/G-X and is the answer not in the manual?

Gree GMV-280WM/G-X Specifications

General IconGeneral
BrandGree
ModelGMV-280WM/G-X
CategoryInverter
LanguageEnglish

Related product manuals