EasyManua.ls Logo

Gree GMV-ND36PHS/B-T User Manual

Gree GMV-ND36PHS/B-T
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Owner's Manual
Original Instructions
Commercial Air Conditioners
Multi Variable Air Conditioners
Ducted Type Indoor Unit
Models:
GMV-ND07PHS/B-T(U)
GMV-ND09PHS/B-T(U)
GMV-ND12PHS/B-T(U)
GMV-ND15PHS/B-T(U)
GMV-ND18PHS/B-T(U)
GMV-ND22PHS/B-T(U)
GMV-ND24PHS/B-T(U)
GMV-ND30PHS/B-T(U)
GMV-ND36PHS/B-T(U)
GMV-ND42PHS/B-T(U)
GMV-ND48PHS/B-T(U)
GMV-ND54PHS/B-T(U)
GMV-ND72PH/B-T(U)
GMV-ND96PH/B-T(U)

Other manuals for Gree GMV-ND36PHS/B-T

Questions and Answers:

Gree GMV-ND36PHS/B-T Specifications

General IconGeneral
BrandGree
ModelGMV-ND36PHS/B-T
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

General Safety Warnings

Covers critical safety precautions for installation, operation, and maintenance to prevent injury or damage.

Product Introduction

Names of Key Components

Identifies key physical components of the indoor unit with diagrams and labels.

Rated Working Condition

Provides operational specifications for indoor and outdoor conditions for cooling and heating.

Preparations for Installation

Standard Fittings

Lists and illustrates standard fittings included with the unit for installation purposes.

Location for Installation

Details ideal placement guidelines and restrictions for the indoor unit to ensure proper function and maintenance.

Requirements for Communication Line

Specifies the type and length of communication wires needed for connecting indoor and outdoor units, including network configurations.

Installation Instructions

Installation of Indoor Unit

Provides detailed steps for installing the indoor unit, including dimensions, suspension, and leveling.

Refrigerant Pipe Connection

Details the correct procedure for connecting refrigerant pipes, including tightening specifications and insulation.

Drainage Pipe Installation and Drainage System Testing

Guides on installing the drain pipe, securing it, insulating it, and conducting tests to ensure proper water drainage.

Installation of Air Duct

Provides instructions and considerations for installing air ducts, including air outlet, air return, and fresh air connections.

Installation of Wired Controller

Directs users to the Wired Controller User Manual for specific installation details and setup.

Wiring Work

Connection of Wire and Patch Board Terminal

Explains how to properly connect wires to terminals using stripping and crimping techniques for reliable connections.

Power Cord Connection

Details the procedure for connecting the power cord, including circuit breaker requirements, wire gauge, and energization.

Connection of Communication Wire between Indoor Unit and Outdoor Unit (or indoor unit)

Guides on connecting the communication wire between indoor and outdoor units or between multiple indoor units for system communication.

Connect Communication Wire of Wired Controller

Details how to connect the communication wire for the wired controller to the indoor unit's terminal board.

Illuminate for Connection of Wired Controller and Indoor Units Network

Explains how to connect wired controllers and indoor units in a network, including master/slave configurations and capacity limits.

Setting of External Static Pressure

External Static Pressure Setting

Describes how to set the external static pressure for the indoor fan using the wired controller or debugging software.

Routine Maintenance

Cleaning of Filter

Provides instructions for cleaning the air filters of the indoor unit to maintain optimal performance and air quality.

Maintenance before the Seasonal Use

Lists essential checks to perform on indoor and outdoor units before the start of the cooling or heating season.

Table of Error Codes for Indoor Unit

Troubleshooting

Related product manuals