3.2 Basic requirement for the installation position
If the product is installed at below places, it may cause malfunction for the air
source water heater. If its unavoidable, please contact local Gree appointed
maintenance center to purchase special models.
(1) There are thermal sources, steam, flammable gas and explosive or volatile
substances.
(2) There are high-frequency equipments, such as welding machines, medical
facilities.
(3) Coastal places.
(4) Theres oil (machine oil) in the air.
(5) Theres sulfureted gas (sulfur spring).
(6) Special places.
3.3 Selection for installation positions
(1) The noise and discharge air wont disturb neighbours, animals or plants.
(2) Make sure the good ventilation for the water heater; air inlet and air outlet of
water heater cant be blocked.
(3) The installation position should bear the weight and vibration for the water
heater.
(4) Select the dry place. The unit cant be exposed at direct sunshine or strong
wind.
(5) Make sure the heat exchanger comply with the requirement of the
installation drawing issue; the unit should be installed at the place wheres
convenient for maintenance and inspection.
(6) Select the place where is beyond the children.
(7) Do not affect the public passage and the city appearance.