QSPEVDU
3.2 Operation Range
Mode Range of Outdoor Temperature
ć
Cooling 18
ć
/-15
ć
--48
ć
Heating -7
ć
-24
ć
3.3 Electrical Data
Model
Compressor
Fan Motor
FLA
Fuse/
Breaker Capacity
Min. Power
Supply Cord
Power Supply Qty. RLA
V,Ph,Hz
—A A A
mm
2
GUHD09NK3CO/GUHD09NK3C1O
220-240
1,
50
1 4.8 0.35 5/16 2.5
GUHD12NK3CO/GUHD12NK3C1O 1 4.8 0.35 5/16 2.5
GUHD18NK3CO/GUHD18NK3C1O 1
8.38
0.58 5/20 4.0
GUHD24NK3CO/GUHD24NK3C1O 1 9.7 0.85 5/20 4.0
GUHD30NK3CO/GUHD30NK3C1O 1 9.7 0.85 5/20 4.0
GUHD36NK3CO/GUHD36NK3C1O 1 13.5 1.1 5/25 4.0
GUHD42NK3CO/GUHD42NK3C1O 1 13.5 1.1 5/25 4.0
GUHD48NK3CO/GUHD48NK3C1O 1 - 0.58 5/32 6.0
GUHD36NM3CO/GUHD36NM3C1O
380-415~
3,
50
1 9.3 1.1 5/16 2.5
GUHD42NM3CO/GUHD42NM3C1O 1 9.3 1.1 5/16 2.5
GUHD48NM3CO/GUHD48NM3C1O 1 - 0.58 5/16 2.5
GUHD60NM3CO/GUHD60NM3C1O 1 - 0.8 5/16
2.5
Model
Power Supply
Fan Motor
FLA
Fuse/
Breaker Capacity
Min. Power Supply
Cord
V,Ph,Hz
AA
mm
2
GFH09K3CI
220-240
1,
50
0.31 5/6
1.0
GTH09K3CI 0.10
5/6
GFH12K3CI 0.41 5/6
1.0GTH12K3CI 0.10
3.15/6
GKH12K3CI 0.2
5/6
GFH18K3CI 0.71 5/6
1.0GTH18K3CI 0.21
3.15/6
GKH18K3CI 0.35
5/6
GFH24K3CI 1.52 5/6
1.0GTH24K3CI 0.51
3.15/6
GKH24K3CI 0.40
5/6
GFH30K3CI 1.52 5/6
1.0GTH30K3CI 0.76
3.15/6
GKH30K3CI 0.61
5/6
GFH36K3CI 5.05 5/6
1.0GTH36K3CI 1.52
3.15/6
GKH36K3CI 0.61
5/6
GFH42K3CI 5.05 5/6
1.0GTH42K3CI 1.52
3.15/6
GKH42K3CI 0.61
5/6