70-15-20
Outdoor temp.(
o
C)
Capacity ratio(%)
 
Conditions
Indoor:DB20°C/WB15°C
Indoor air flow:Super High
Pipe length: 5m
2.3 Cooling Data Sheet in Rated Frequency
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
 
Connection pipe length: 5 m.
Rated cooling condition(°C) 
(DB/WB)
Model 
Pressure of gas pipe 
connecting indoor and 
outdoor unit 
Inlet and outlet pipe 
temperature of heat exchanger
Fan speed 
of indoor 
unit
Fan speed 
of outdoor 
unit 
Indoor Outdoor  P (MPa)  T1 (°C) T2 (°C)
27/19 35/24 24K 0.58 to 1.0
in:8~11
out:11~14
in:75~85
out:37~43
Super High High
27/19 35/24 48/55K 0.8 to 0.9
in:8~11
out:11~14
in:75~85
out:37~43
Super High High
Rated heating condition(°C) 
(DB/WB)
Model 
Pressure of gas pipe 
connecting indoor and 
outdoor unit 
Inlet and outlet pipe 
temperature of heat 
exchanger
Fan speed of 
indoor unit
Fan speed of 
outdoor unit 
Indoor Outdoor  P (MPa)  T1 (°C)  T2 (°C) 
20/- 7/6 24K 2.5 to 3.0
in:75~85
out:37~43
in:1~3
out:3~5
Super High High
20/- 7/6 48/55K 3.0 to 3.1
in:75~85
out:37~43
in:1~3
out:3~5
Super High High