47
Technical Information
Service Manual
(1) When Toutdoor amb.≤≤23ºF , compressor stops operation,
while the electric heating of compressor starts operation;
(2) When Toutdoor amb.>28.4ºF , the electric heating of
compressor stops operation;
(3) When 23ºF <Toutdoor amb.≤28.4ºF , the electric heating of
compressor will keep original status.
6. Electric Heating Function of Chassis
(1) When Toutdoor amb.≤32ºF , the electric heating of chassis will
operate;
(2) When Toutdoor amb.>35.6ºF , the electric heating of chassis
will stop operation;
(3)When 32ºF <Toutdoor amb.≤35.6ºF, the electric heating of
chassis will keep original status.
7. Electric Heating Function of Compressor
(1) When Toutdoor amb.≤≤23ºF , compressor stops operation,
while the electric heating of compressor starts operation;
(2) When Toutdoor amb.>28.4ºF , the electric heating of
compressor stops operation;
(3) When 23ºF <Toutdoor amb.≤28.4ºF , the electric heating of
compressor will keep original status.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWC and is the answer not in the manual?

Gree GWC Specifications

General IconGeneral
Power Supply220-240V, 50Hz
TypeSplit
RefrigerantR410A
FeaturesAuto Restart, Sleep Mode, Turbo Mode
EER (Energy Efficiency Ratio)3.5
Noise Level50 dB (Outdoor)
Cooling Capacity12000 BTU/h
Heating Capacity12000 BTU/h
WeightIndoor: 9 kg, Outdoor: 30 kg

Related product manuals