49
Installation and Maintenance
Service Manual
Safety Precautions for Installing and Relocating the Unit:
To ensure safety, please be mindful of the following precautions.
1. When installing or relocating the unit, be sure to keep the
refrigerant circuit free from air or substances other than the
specied refrigerant.
Any presence of air or other foreign substance in the refrigerant
circuit will cause system pressure rise or compressor rupture,
resulting in injury.
2. When installing or moving this unit, do not charge the
refrigerant which is not comply with that on the nameplate or
unqualied refrigerant.
Otherwise, it may cause abnormal operation, wrong action,
mechanical malfunction or even series safety accident.
3. When refrigerant needs to be recovered during relocating
or repairing the unit, be sure that the unit is running in
cooling mode.Then, fully close the valve at high pressure
side (liquid valve).About 30-40 seconds later, fully close the
valve at low pressure side (gas valve), immediately stop
the unit and disconnect power. Please note that the time for
refrigerant recovery should not exceed 1 minute.
If refrigerant recovery takes too much time, air may be sucked in
and cause pressure rise or compressor rupture, resulting in injury.
4. During refrigerant recovery, make sure that liquid valve
and gas valve are fully closed and power is disconnected
before detaching the connection pipe.
If compressor starts running when stop valve is open and
connection pipe is not yet connected, air will be sucked in and
cause pressure rise or compressor rupture, resulting in injury.
5. When installing the unit, make sure that connection pipe
is securely connected before the compressor starts running.
If compressor starts running when stop valve is open and
connection pipe is not yet connected, air will be sucked in and
cause pressure rise or compressor rupture, resulting in injury.
6. Prohibit installing the unit at the place where there may be
leaked corrosive gas or ammable gas.
If there leaked gas around the unit, it may cause explosion and
other accidents.
7. Do not use extension cords for electrical connections. If
the electric wire is not long enough, please contact a local
service center authorized and ask for a proper electric wire.
Poor connections may lead to electric shock or re.
8. Use the specied types of wires for electrical connections
between the indoor and outdoor units. Firmly clamp the
wires so that their terminals receive no external stresses.
Electric wires with insufcient capacity, wrong wire connections
and insecure wire terminals may cause electric shock or re.
WARNINGS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWC and is the answer not in the manual?

Gree GWC Specifications

General IconGeneral
Power Supply220-240V, 50Hz
TypeSplit
RefrigerantR410A
FeaturesAuto Restart, Sleep Mode, Turbo Mode
EER (Energy Efficiency Ratio)3.5
Noise Level50 dB (Outdoor)
Cooling Capacity12000 BTU/h
Heating Capacity12000 BTU/h
WeightIndoor: 9 kg, Outdoor: 30 kg