63
Installation and Maintenance
Service Manual
No. Malfunction Name
Display Method of
Indoor Unit
A/C status Possible Causes
Dual-8 Code
Display
47
Malfunction of detecting
plate(WIFI )
JF
Loads operate normally, while the unit can’t be
normally controlled by APP.
1. Main board of indoor unit is damaged;
2. Detection board is damaged;
3. The connection between indoor unit and
detection board is not good;
48
Refrigerant recovery
mode
Fo
Refrigerant recovery. The Serviceman operates
it for maintenance.
49
Undened outdoor unit
error
oE
Cool: compressor and outdoor fan stops
operation, while indoor fan operates; Heat:
compressor, outdoor fan and indoor fan stop
operation.
1. Outdoor ambient temperature exceeds the
operation range of unit (eg: less than-20
o
C or
more than 60
o
C for cooling; more than 30
o
C for
heating);
2. Failure startup of compressor?
3. Are wires of compressor not connected
tightly?
4. Is compressor damaged?
5. Is main board damaged?

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWC and is the answer not in the manual?

Gree GWC Specifications

General IconGeneral
Power Supply220-240V, 50Hz
TypeSplit
RefrigerantR410A
FeaturesAuto Restart, Sleep Mode, Turbo Mode
EER (Energy Efficiency Ratio)3.5
Noise Level50 dB (Outdoor)
Cooling Capacity12000 BTU/h
Heating Capacity12000 BTU/h
WeightIndoor: 9 kg, Outdoor: 30 kg