Loading...
19
Technical Information
Service Manual
5. Electrical Part
5.1 Wiring Diagram
● Indoor Unit
●Instruction
Symbol Symbol Color Symbol Symbol Color Symbol Name
WH White GN Green CAP Jumper cap
YE Yellow BN Brown COMP Compressor
RD Red BU Blue Grounding wire
YEGN Yellow/Green BK Black / /
VT Violet OG Orange / /
Note: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model.
L-OUT
L1
L1
θθ
RT1RT2
M
JUMP
CAP
TEM.SENSOR
ROOM
TUBE
TEM.SENSOR
FAN MOTOR
SWING MOTOR(U.D)
AP2
SWING-UD
K4
TUBEROOM
AC-L
PG
PGF
DISP-1 DISP-2
CN2
CN1
AP1
DISPLAY
GENERATOR
COOL PLASMA
M
PE
XT1
W1 BU
W3 BN
N(1)
OUTDOOR UNIT
2
3
COM-OUT
W4 YEGN
N
W2 BK
BU
YEGN
BN
L
N
POWER
RD BU
YEGN
HEALTH-NHEALTH-L
PE
BU
BK
BN
YEGN
EVAPORATOR