80
Service Manual
Installation and Maintenance
6.Remove swing fan blade
a Loosen the clamps fixing swing connecting
rod, to remove the swing connecting rod.
b
remove the swing fan blade.
a Remove the indoor tube temp. sensor.
bRemove the screws fixing earth wire, to
remove the earthwire.
swing fan blade
clamp
clamp
swing connecting rod
7.Remove electric box sub-assy
heat exchanger thermistor
screw
earth wire